Actions

Difference between revisions of "IP-DECT server 6000"

From Zenitel Wiki

(General Configuration)
(General Configuration)
Line 34: Line 34:
 
  4 In the Netmask field, type in the network mask.  
 
  4 In the Netmask field, type in the network mask.  
 
  5 In the Gateway field, type in the IP address of the default gateway.
 
  5 In the Gateway field, type in the IP address of the default gateway.
  6 In the Server field (under NTP - Network Time Protocol), type the IP address of the NTP server from which
+
  6 In the Server field (under NTP - Network Time Protocol), type the IP address of the NTP server from  
   the system will obtain the current time (optional).
+
   which the system will obtain the current time (optional).
 
  7 From the Time Zone list, select the wanted time zone (optional).
 
  7 From the Time Zone list, select the wanted time zone (optional).
 
  8 Click Save to save your general configuration data.
 
  8 Click Save to save your general configuration data.

Revision as of 15:12, 30 April 2009

This article describes how to setup the STENTOFON IP-DECT Server 6000 to work with the AlphaCom E using the SIP protocol.

Configuration example


Configuration of AlphaCom E

The AlphaCom E needs to be configured with a SIP registrar node, and must be equipped with license for SIP stations.


Configuration of STENTOFON IP-DECT

Getting access to the embedded web server

GENERAL STATUS page - Logged on to IP address 192.168.0.1

Load factory default configuration on the IP-Dect Server by pressing the reset button through the hole at the rear with an unbend paper clip for 10 sec.

Before the PC can access the IP Dect Server, the IP address of the PC must be changed to match the same subnet (for example 192.168.0.2). To access the embedded web server of the IP-Dect Server, start your internet browser (e.g. Internet Explorer) and in the address field enter 192.168.0.1. You will be prompted for a username and password. Default: admin and ip6000 (case senstive).
Default:

Username: admin
Password: ip6000

The GENERAL STATUS page should now be displayed:



General Configuration

On the General Configuration page you define IP, DNS and NTP settings for the STENTOFON IP-DECT Server 6000.

General Configuraion
1 Click Configuration, and then click General.
2 Click Use Static IP Address.
3 In the IP Addr field, type in the IP address of the IP-DECT Server.
4 In the Netmask field, type in the network mask. 
5 In the Gateway field, type in the IP address of the default gateway.
6 In the Server field (under NTP - Network Time Protocol), type the IP address of the NTP server from 
  which the system will obtain the current time (optional).
7 From the Time Zone list, select the wanted time zone (optional).
8 Click Save to save your general configuration data.

Leave the rest blank. All changes to fields marked with two stars need a reboot to take effect

Wireless Server Configuration

On the Configuration/Wireless Server page you configure the STENTOFON IP-DECT Server 6000 to allow subscription. If the system does not allow subscription, it is not possible to subscribe a handset.

Wireless Server Configuration
1 Click Configuration, and then click Wireless Server.
2 Select the Subscription Allowed check box (optional).
  * Note: If not selected, you cannot subscribe a handset.
3 Click Save.

Built-In Media Resource Configuration

On the Configuration/Media Resource page you configure the built-in Media Resource.

Media Resource Configuration
1 Click Configuration, and then click Media Resource.
2 In the Host field, type localhost if you want to activate the built-in media resource.
3 Click Save.


IP-DECT Server 6000 SIP Configuration

On the Configuration/SIP page you define general SIP settings, information about authentication, DTMF signalling, message waiting indication and media.

SIP Configuration
1 Click Configuration, and then click SIP.
2 In the Local Port field, type the local port number. The default local port number is 5060.
* Note: The local port is the port on which the KWS6000 listens for incoming SIP-signalling.
3 In the Default Domain field, type the name of the domain. For example AlphaCom.com.
4 In the Proxy field, type in the IP address of your AlphaCom.
  * Note: The proxy is the SIP URI of the SIP-proxy. The IP-DECT Server 6000 will route all outgoing SIP 
  signalling to the proxy, e.g. SIP registrations and outgoing calls.
5 In the Registation Expire(sec) field, type the number of seconds before a SIP registration will be 
  renewed. The default value is 3600.
6 In the Max Forwards field, type a value (optional). The default value is 70.
7 From the SIP Type of Service list, select between Nothing, Low delay, Reliability, Throughput and 
  Minimum cost. The default setting is Nothing.
8 In the Default User field, type the user name. For example "Alpha"
9 In the Default Password field, type the password (optional).
  * Note: If no handset specific authentication user name/password is configured, handsets registered on 
  the IP-DECT Server 6000 will use the default user name/password for authentication.
10 Select the Send as SIP INFO check box if you want the keypad signalling sent as SIP INFO packets with 
   DTMF code (optional).
   * Note: Must be set to SIP INFO to enable door opening via SIP.
11 In the Tone Duration(msec) field, type the time length of the tone in miliseconds. 
   The default value is 270.
12 Select the Enable Indication check box, if you want to handle MWI message (optional).
14 Select the Enable Subscription check box, if you want to subscribe to MWI indications from the 
   SIP proxy (optional).
15 In the Subscription Expire(sec) field, type a value. The default value is 3600.
16 From the Packet Duration(msec) list, select 20.
17 From the Media Type of Service list, select between Nothing, Low delay, Reliability, Throughput and 
   Minimum cost.The default setting is nothing.
18 In the Port Range Start field, type a value. The default value is 58000.
19 In the Codec priority fields, select PCMU/8000 for fild number 1. Set the rest to "None".
20 Click Save to save your SIP configuration data.

Base Station Configuration

Powering up the Base Station

After installing the base station you need to power it up. The base station uses: • Power over Ethernet (PoE 802.3af). • Maximum power supply consumption is 3.0W (IEEE 802.3af class 1 device). Use a standard PoE adapter or a PoE-enabled port on a switch adhering to PoE 802.3af when connecting the base station to a PoE power source.

Accessing the Web Based Administration Page

In order for your computer to communicate with the base station it is necessary to change the computer’s Internet Protocol Properties to use the following: • IP address: 192.168.0.2 • Sub-net mask: 255.255.255.0

The web based Administration Page is accessed through a standard web browser.

1 Open a web browser.
2 In the browsers Address bar, type http://192.168.0.1, and then press ENTER.
  * Note: The base station is pre-configured with the IP address: 192.168.0.1 through the ETH port.

The Administration Page for the base station appears. First time you access the Administration Page, you need to log on with user name and a password. Default:

Username: admin
Password: ip6000

Configuring a Base Station Using Static IP Address

This section describes how to configure a base station using static IP address.

General Configuration

On the General Configuration page you define IP and DNS settings for the base station.

1 Click Configuration, and then click General.
2 Click Use static IP address.
3 In the IP addr field, type the IP address of the base station.
4 In the Netmask field, type the network mask.
5 In the Gateway field, type the IP address of the default gateway (optional).The default gateway serves as an access point to another network.
  Contact your system administrator for more information.
6 In the MTU field (Maximum Translation Unit), type the size of the largest packet, that your network protocol can transmit (optional).
7 In the Domain field, type the domain name of the system (optional).
8 In the Server field (under DNS - Domain Name System), type the IP address of the domain name (optional).

Base Station Configuration

How to configure the base station:

1 Click Configuration, and then click Base station.
2 In the Host field, type the host name or the IP address of the IP-DECT Server 6000.
3 Click Save.
4 Click Reboot to enable the configuration changes.

Synchronization Ways Configuration

If there is more than one base station, a synchronization master needs to be set. This is done in the IP-DECT Server 6000, under Administration -> Base Station. It is necessary to define the synchronization ways of the base station.

1 To define the sync. ways of the base station, open the Administration Page for the IP-DECT Server 6000.
2 Click Administration, and then click Base Station.
3 Double-click on the relevant base station in the list.
4 In the RPN field (Radio Part Number), type the radio part number of the base station. The radio ID can be a number between 0 and 255. 
  See your site planner. Value 0 = Synchronization Master.
  * Note: The default value of the RPN is equal to the base station number. It is strongly recommended not to change this value.
5 It is possible to select Auto sync if you are deploying and want to find a sync way for the first base station.
  * Note: Auto sync is only to be used in a deployment situation. When selecting Auto sync, radio part numbers in the Primary sync. (RPN)
  field and Secondary sync. (RPN) field are not taken into consideration.
6 In the Primary sync. (RPN) field, type the radio part number of the base station, you want to synchronize on. See your site planner.
7 In the Secondary sync. (RPN) field, type the radio part number of the base station, you want to synchronize on. See your site planner.
8 Click Save. 
9 Click Restart to enable the configuration changes.

Checking Indicators

Verify that the base station LED indicator is continuously on, indicating that the base station is functional.

Handset Registration and Subscription

This section provides information about handset registration and subscription. You must register and subscribe a handset before you can use it. When registering handsets you enter information about the handsets settings (such as; the handsets serial number (IPEI), name etc.) in the system database. When subscribing handsets you subscribe a registered handset to the system for usage. If the handset is not registered in the system database, subscription of the handset is not possible.

Registering IP-DECT Handsets

To register handsets you use the web based Administration Page of the STENTOFON IP-DECT Server 6000. Each handset in the wireless solution must be programmed with the serial number (IPEI) before it can operate. This serial number must be registered in the web based Administration Page of the IP-DECT Server. Serial numbers are a unique fingerprint of each handset. The serial number is programmed into the handset during the manufacturing process and cannot be changed by field personnel.

1 Click Configuration and then click List Users.
2 Click New.

The data configured for each handset can be split into two categories. DECT data which is necessary for the correct handling of the DECT protocol stack. SIP data which is necessary for the handling of a SIP user agent.

3 In the IPEI field, type the IPEI number (serial number) of the handset. The serial numner consist of a five-digit handset type (manufacturer
  code) and a seven-digit handset number.
  * Note The IP-DECT Server 6000 does not provide any service to a handset whose serial number is not registered in the web based
  Administration Page.
4 In the Access code field, type the authentication code (AC) (optional). The authentication code is a subscription password of a maximum of  
  eigth digits, defined by the technicians, and can be used when connecting the handset to a IP-DECT Server. The authentication code is a 
  subscription pin code for the individual handset.
5 In the Standby text field, type a text to be displayed when the handset is on hook (optional).
6 In the Username field, type the user part of a SIP URI, for example 201.
7 In the Domain field, type the domain part of a SIP URI, for example AlphaCom.com (optional).
  *Note: If not configured, the default domain will be used.
8 In the Displayname field, type the name to be displayed (caller ID).
9 In the Authentication user field, type a user name (optional).
10 The user name will override the Default User field under SIP Configuration.
11 In the Authentication password field, type a password (optional). The password will override the Default Password field under 
   SIP Configuration.
12 In the Local number field, type the local number of the handset (optional). Typing a local number makes it possible to send an MSF to the    
   subscribed handset.
13 Click Save to save the registration(s).

Subscribing IP-DECT Handsets

A handset can be subscribed to more systems and will automatically log on to the relevant system. If a handset is subscribed to two or more systems, you can use Auto Login type A to change between the systems automatically. If a handset is subscribed to two systems only, you can use Auto Login type B to change between the systems automatically. When to use Auto Login type A:

  • Auto Login A should only be used in separate systems without overlaps.
If a handset looses signal from the system (the display showing Out of Range), then after 20 seconds the handset will start searching for an
alternative system available from the Login list and automatically change to this system.
* Note: Using Auto Login A any call will be dropped when changing to an alternative system.

When to use Auto Login type B:

  • Auto Login B can be used in separate systems which are overlapping each other.
As soon as the handset has measured a low RSSI signal 5 times in succession, it will start up the Auto Login type B procedure and change to
an alternative system available.
*Note: Using Auto Login B any call will be dropped when changing to an alternative system.

In some situations it is necessary to use Auto Login type B due to the following:

If two separate systems are sharing areas with common overlap, selecting Auto Login type A will result in poor performance as the handset will
stay connected to the actual system it is subscribed to for as long as it can recognize a signal. Even if the bearer quality of the actual  
system is so bad that it cannot setup a connection, it is still not possible for the handset to change to alternative systems. Auto Login type  
B can enhance the performance for such configurations. Using Auto Login type B the handset is forced to switch from a system with bad bearer 
quality to one of the alternative systems available. To determine if it is necessary to log on to another system the handset is measuring the 
RSSI level. A number of measured low RSSI levels will force the handset to log on to the alternative system.

Rough and EX Handsets

1 Press MENU - go to MENU LOGIN.
2 Press V - go to SUBSCRIPTION CREATE to subscribe to a system.
3 Press V. The handset searches for the serial number of the system.
4 Use the < > keys to scroll between the IDs systems if there is more than one system available. During subscription, the handset searches for  
  free positions and performs subscription on the first free position.
5 As soon as the correct serial number of the system appears in the display, press V. The serial number is located on the label on the
  rear of the STENTOFON IP-DECT Server 6000.
6 Enter the AC (if required) using the keyboard, and press V.

An antenna symbol appears on the display to indicate a successful subscription. If not, the subscription has failed and the procedure must be retried.

Subscribing a Rough or EX Handset to Different Systems

The handset can be subscribed (connected) to a maximum of 10 different systems.
Changing to another System Automatically Using Auto Login A

1 Press MENU - go to MENU LOGIN.
2 Press V - go to SELECT LOGIN.
3 Press V - go to SELECT LOGIN AUTO A.
4 Press V.

The handset automatically selects a system. The selected system is marked with an A.

  • Note: To be able to log on to a system, subscription to the system must be established.
  • Note: Auto Login A should only be used when systems are separate, with no overlaps.

Changing to another System Automatically Using Auto Login B

1 Press MENU – go to MENU LOGIN.
2 Press V – go to SELECT LOGIN.
3 Press V – go to SELECT LOGIN AUTO B.
4 Press V.

The handset automatically selects a system. The selected system is marked with a B.

Changing to another System Manually
If you would like to change to another system:

1 Press MENU - go to MENU LOGIN.
2 Press V - go to SELECT LOGIN to subscribe to a system. The actual chosen system is marked with an * or an A (if auto login is
  selected).
3 Press V - use the < > keys to scroll between the IDs of the different systems to find the system to which you want to connect.
  Under SELECT LOGIN only subscriptions display. Free positions do not display.
4 Press V to confirm.

Office Handsets

1 Press Menu to enter main menu.
2 Scroll to Settings and press Select.
3 Scroll to Advanced and press Select.
4 Scroll to Login and press Select. 
5 Scroll to Create login and press Select. The handset will start searching for a system.
6 Scroll to the found system and press Select. 
7 Enter an AC Code and press Ok to connect to the system.
8 Press Ok.
Subscribing an Office Handset to Different Systems

The handset can be subscribed (connected) to a maximum of 10 different systems. Changing to another System Automatically Using Auto Login A

1 Press Menu to enter main menu.
2 Scroll to Settings and press Select.
3 Scroll to Advanced and press Select.
4 Scroll to Login and press Select.
5 Scroll to Auto login and press Select.
6 If Off is selected, press Change to select On.
7 Press R to return to standby mode.

The handset automatically selects a system. The selected system is marked with an A.

Changing to another System Manually If you would like to change to another system:

1 Press Menu to enter main menu.
2 Scroll to Settings and press Select.
3 Scroll to Advanced and press Select.
4 Scroll to Login and press Select.
5 Scroll to Select login and press Select.
6 Scroll to the desired login and press Select.

Related articles