Difference between revisions of "Logging into an Zenitel IP Device"
From Zenitel Wiki
(25 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | {{ | + | {{AEPS}} |
− | + | Access the web interface of an IP station (or any Vingtor-Stentofon IP device) with a standard web browser: | |
− | Access the web interface of an IP station with a standard web browser: | + | # Open a web browser |
− | + | # In the browser’s address bar, type the station IP address and press the ENTER key | |
− | + | [[File:StartingUP IPStation.png|thumb|right|500px|Connect the PC and the station to a network switch, and open a webbrowser to log on to the station]] | |
::- The station login page will be displayed. | ::- The station login page will be displayed. | ||
[[File:StationLogin.PNG|thumb|left|500px|The login page]] | [[File:StationLogin.PNG|thumb|left|500px|The login page]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
To log into the station: | To log into the station: | ||
− | + | # Click on one of the login options | |
− | + | # Enter the default User name: '''admin''' | |
− | + | # Enter the default Password: '''alphaadmin''' | |
The '''Station Information''' page will now be displayed, showing the IP station configuration and status. | The '''Station Information''' page will now be displayed, showing the IP station configuration and status. | ||
+ | |||
+ | <br> | ||
== Default IP addresses == | == Default IP addresses == | ||
− | * The [[:Category: | + | * The [[:Category:Stations#INCA_stations|INCA series of stations]] has default IP address '''169.254.1.100'''. |
− | * The [[:Category: | + | * The [[:Category:Stations#Turbine_stations|Turbine series of stations]] are set to obtain IP address automatically from the network (DHCP). If no DHCP server present, it will get a random '''169.254.x.x''' address The station will speak its own IP address when pressing the '''Call button''', a '''Digit key''' a '''DAK key''' or activate an '''Input''' of the station. |
+ | |||
+ | <br> | ||
+ | |||
+ | == How to set a static IP Address on your Windows 10 computer == | ||
+ | In order to access the web interface of the station, your computer must be in the same subnet range as the station. | ||
+ | # Click '''Start''', and type '''Control''' in the search field, then select '''Control Panel'''. | ||
+ | #Click on '''Network and Internet'''. | ||
+ | #Click on '''Network and Sharing Center'''. | ||
+ | #On the left pane, click the '''Change adapter settings''' link. | ||
+ | #Right-click the network adapter and select '''Properties'''. | ||
+ | #Select the '''Internet Protocol Version 4 (TCP/IPv4)''' option. | ||
+ | #Click the '''Properties''' button. | ||
+ | #Select the '''Use the following IP address''' option. | ||
+ | #Set the '''IP address''' (e.g., '''169.254.1.90'''). | ||
+ | #Set the '''Subnet mask'''. (e.g., '''255.255.0.0'''). | ||
+ | #Set the '''Default gateway'''. This address is typically your router’s IP address (e.g., '''169.254.1.1'''). | ||
+ | #Click '''OK'''. | ||
+ | #Click '''Close''' again to close the network adapter properties. | ||
+ | |||
+ | [[File:PC StaticIP.PNG|thumb|left|500px|Setting a Static IP Address]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
+ | Once you’ve completed the steps, you can open your web browser and try logging into the station. | ||
+ | |||
+ | ---- | ||
+ | {{Doc|This article is linked to from the document A100K11920}} | ||
+ | [[Category: IC-EDGE Configuration]] | ||
[[Category: Pulse - Configuration]] | [[Category: Pulse - Configuration]] | ||
[[Category: SIP intercom - Configuration]] | [[Category: SIP intercom - Configuration]] |
Revision as of 17:37, 29 March 2019
Access the web interface of an IP station (or any Vingtor-Stentofon IP device) with a standard web browser:
- Open a web browser
- In the browser’s address bar, type the station IP address and press the ENTER key
- - The station login page will be displayed.
To log into the station:
- Click on one of the login options
- Enter the default User name: admin
- Enter the default Password: alphaadmin
The Station Information page will now be displayed, showing the IP station configuration and status.
Default IP addresses
- The INCA series of stations has default IP address 169.254.1.100.
- The Turbine series of stations are set to obtain IP address automatically from the network (DHCP). If no DHCP server present, it will get a random 169.254.x.x address The station will speak its own IP address when pressing the Call button, a Digit key a DAK key or activate an Input of the station.
How to set a static IP Address on your Windows 10 computer
In order to access the web interface of the station, your computer must be in the same subnet range as the station.
- Click Start, and type Control in the search field, then select Control Panel.
- Click on Network and Internet.
- Click on Network and Sharing Center.
- On the left pane, click the Change adapter settings link.
- Right-click the network adapter and select Properties.
- Select the Internet Protocol Version 4 (TCP/IPv4) option.
- Click the Properties button.
- Select the Use the following IP address option.
- Set the IP address (e.g., 169.254.1.90).
- Set the Subnet mask. (e.g., 255.255.0.0).
- Set the Default gateway. This address is typically your router’s IP address (e.g., 169.254.1.1).
- Click OK.
- Click Close again to close the network adapter properties.
Once you’ve completed the steps, you can open your web browser and try logging into the station.