Actions

Difference between revisions of "RCO CHANGED"

From Zenitel Wiki

 
(8 intermediate revisions by one other user not shown)
Line 1: Line 1:
{{A}}
+
{{AI}}
 
{| border="1"  
 
{| border="1"  
 
|-
 
|-
Line 9: Line 9:
 
|colspan="5"|'''$RCOC W1 U1'''
 
|colspan="5"|'''$RCOC W1 U1'''
 
|-
 
|-
|colspan="5"|New [[RCO]] pin state reported from exchange.
+
|colspan="5"|[[RCO]] pin state reported from exchange.
Note:  Message is NOT sent automatically from exchange.  Must be configured in Event Handler as “side effect” of [[RCO]] controlling actions (possibly using [[UDP]] to handle many similar [[RCO]] operations)
+
 
 +
This message is (since 2010?) sent automatically from the AlphaCom server to registered OPC devices on TCP ports 61112 and 61113 as a respose to an [[RCO - Set Remote Control Output|RCO command]] or [[SET LOGICAL RCO|$SLRC command]]
 
|-
 
|-
 
|align=center|1||[[UINT2]]||colspan="3"|Logical [[RCO]] number  
 
|align=center|1||[[UINT2]]||colspan="3"|Logical [[RCO]] number  
 
|-
 
|-
 
|align=center|2||[[UINT1]]||colspan="3"|Change to state:
 
|align=center|2||[[UINT1]]||colspan="3"|Change to state:
0 = pin is off
+
*0 = pin is off
 
+
*1 = pin is on
1 = pin is on
 
 
|-
 
|-
 
|}
 
|}

Latest revision as of 16:05, 3 October 2019

AI.png
RCO_CHANGED 0x0085 133 AMC 08.10
$RCOC W1 U1
RCO pin state reported from exchange.

This message is (since 2010?) sent automatically from the AlphaCom server to registered OPC devices on TCP ports 61112 and 61113 as a respose to an RCO command or $SLRC command

1 UINT2 Logical RCO number
2 UINT1 Change to state:
  • 0 = pin is off
  • 1 = pin is on


Back to AlphaNet message list