Actions

Difference between revisions of "Remote setup of Alarm message feature"

From Zenitel Wiki

Line 10: Line 10:
 
|'''Parameter 1''': || 0 (N/A)
 
|'''Parameter 1''': || 0 (N/A)
 
|-valign="top"  
 
|-valign="top"  
|'''Description''': || Remotely activate playback of [[alarm message]] to another station or [[groups|group]] of stations. The feature requires [[ASVP]] board.
+
|'''Description''': || Remotely activate playback of [[alarm message]] to another station or [[groups|group]] of stations.  
 
Procedure:
 
Procedure:
 
* 761 + [[Group call feature|group]] + [[Start Alarm message at station feature|alarm message]]
 
* 761 + [[Group call feature|group]] + [[Start Alarm message at station feature|alarm message]]

Revision as of 16:17, 16 May 2018

Feature: Remote setup of Alarm Message
Default directory number: 761
Feature number: 68
Parameter 1: 0 (N/A)
Description: Remotely activate playback of alarm message to another station or group of stations.

Procedure:

  • 761 + group + alarm message
  • 761 + 85 + 8191: Turn on alarm message 8191 to stations in group 85
  • 761 + 85 + 8190: Turn off alarm message to stations in group 85


This feature is by default available for SuperUser only.

Alarm messages can also be triggered from the Event Handler or RCI by using the commands AMS or AMG, or the AlphaCom Data Protocol command $ALRM

By default an alarm message will be repeated endlessly, until switched off. However, it is possible to specify a specific number of repetitions for each alarm message. This must be done from the nvram editor in the TST console.




Back to feature list