Actions

Difference between revisions of "SET LOGICAL RCO"

From Zenitel Wiki

 
Line 10: Line 10:
 
|-
 
|-
 
|colspan="5"|Set or clear a logical [[RCO]].  Mapping between logical and physical [[RCO]] is done by the exchange receiving this message.
 
|colspan="5"|Set or clear a logical [[RCO]].  Mapping between logical and physical [[RCO]] is done by the exchange receiving this message.
Note: [[COMMAND_RESPONSE]] is returned at the time the destination node receives the message, not after the RCO­pin has been actually set/cleared.  
+
Note: [[COMMAND_RESPONSE]] is returned at the time the destination node receives the message, not after the RCO ­pin has been actually set/cleared.  
 
|-
 
|-
 
|align=center|1||[[UINT2]]||colspan="3"|Logical [[RCO]] number.
 
|align=center|1||[[UINT2]]||colspan="3"|Logical [[RCO]] number.

Latest revision as of 14:37, 13 November 2023

AI.png
SET_LOGICAL_RCO 0x006B 107 AMC 07.00
$SLRC W2 U1
$SLRC W2 U1 W10
Set RCO #2
Set RCO #2 for 1 second
Set or clear a logical RCO. Mapping between logical and physical RCO is done by the exchange receiving this message.

Note: COMMAND_RESPONSE is returned at the time the destination node receives the message, not after the RCO ­pin has been actually set/cleared.

1 UINT2 Logical RCO number.
2 UINT1 New pin state:

0 = turn output off

1 = turn output on

3 UINT2 Duration of pulse, in tenths of second. Optional, new in AMC 10.03. If Duration parameter is present, and non-zero, the RCO state specified in previous parameter lasts for the specified time. After the time has expired, the RCO is toggled to the opposite state. If a new $SLRC message on the same RCO arrives while the pulse timer is running, the timer is canceled, and the new message determines the new RCO state. Duration = 0 means infinite duration.
Response: COMMAND_RESPONSE


Back to AlphaNet message list