Actions

Difference between revisions of "Store backup to FLASH memory feature"

From Zenitel Wiki

Line 14: Line 14:
  
 
Note: The backup.bin file is compatible within the same AMC Database version only.
 
Note: The backup.bin file is compatible within the same AMC Database version only.
 
Different AMC Database versions! The running configuration will be deleted and factory default settings will be generated.
 
Before continuing you must create a backup of the running configuration by doing a GetAll operation from AlphaPro.
 
Note: A backup.bin file created from AlphaWeb or by the feature code 7820 is compatible within the same AMC Database version only, and cannot be used to restore the configuration.
 
 
<br>
 
'''7820 Backup''': The running configuration is restored from the backup file (backup.bin) every time the exchange reset. When using this backup option, a master backup (7821) should be made every time the configuration is changed, if not the changes are lost after next reset or power off.<br>
 
'''7821 Master Backup''': The running configuration is restored from the backup file (backup.bin) every time the exchange reset. When using this backup option, a master backup (7821) should be made every time the configuration is changed, if not the changes are lost after next reset or power off.
 
 
|}
 
|}
  
  
 
[[AlphaCom Feature List|Back to feature list]]
 
[[AlphaCom Feature List|Back to feature list]]

Revision as of 17:40, 2 January 2008

Feature: Backup of running configuration to on-board file
Default directory number: 7820, 7821
Feature number: 41
Parameter 1: 0 = Backup (7820)

2 = Master Backup (7821)

Description: Backup of the running configuration to a on-board file called backup.bin. The file is stored in the flash memory, and survives autoload. A backup is made by dialling 7820 (or 7821) + M-key on a SuperUser station.

Note: The backup.bin file is compatible within the same AMC Database version only.