Actions

Difference between revisions of "TAX-2B"

From Zenitel Wiki

(Related article)
 
(9 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
__NOTOC__
 
__NOTOC__
[[File:1008150025.PNG|thumb|500px]]
+
[[File:1008150025.PNG|thumb|300px|TAX-2B: Plugbox with 10 meter cable]]
 
+
TAX-2b is an Ex-Approved Plugbox & Cable for Headset with PTT.
===<u>Highlights</u>===
+
==Highlights==
 
* 10m cable for EX-areas
 
* 10m cable for EX-areas
 
* Compact, rugged plugbox with PTT for Industrial application
 
* Compact, rugged plugbox with PTT for Industrial application
Line 9: Line 9:
 
* Designed for Exigo & Turbine EX explosion-proof intercoms
 
* Designed for Exigo & Turbine EX explosion-proof intercoms
  
===<u>Connecting TAX-2b Plugbox to TFIX series Intercoms</u>===
 
Connect the wire ferrules on the Plugbox cable to the terminal block according to the pin configuration below. Note that the black (shield) wire is labeled '''MIC-''' and the black (main shield) wire is labeled '''GND'''.
 
  
[[File:TAX-22b connections.PNG|thumb|left|500px|Connecting TAX-2b Plugbox to TFIX series Intercoms]]
+
==Connecting TAX-2b Plugbox to TFIX series Intercoms==
 +
Connect the wire ferrules on the Plugbox cable to the [[TFIX Connections|terminal block]] according to the pin configuration below. Note that the black (shield) wire is labeled '''MIC-''' and the black (main shield) wire is labeled '''GND'''.
 +
 
 +
[[File:TAX-22b connections.PNG|thumb|left|400px|Connecting TAX-2b Plugbox to TFIX series Intercoms]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
===<u>Additional Documentation</u>===
 
For more documentation please see https://www.zenitel.com/product/tax-2b
 
  
===<u>[http://www.zenitel.com/product/tax-2b Additional Documentation on Zenitel.com]</u>===
+
==Connecting TAX-2b Plugbox to TFIX-V2 series Intercoms==
 +
Connect the wire ferrules on the Plugbox cable to the connectors according to the pin configuration below. Note that the black (shield) wire is labeled '''MIC-''' and the black (main shield) wire is labeled '''GND'''.
 +
 
 +
[[File:Connection of Headset AK5850HS and Plugbox TAX-2B on TFIX-V2.png|thumb|left|500px|Connection of Headset AK5850HS and Plugbox TAX-2B on TFIX-V2]]
 +
<br style="clear:both;" />
  
===<u>Related article</u>===
 
[[ATEX Headset - AK5850HS]]
 
  
 +
==Related Information ==
 +
*[[ATEX Headset - AK5850HS]]
 +
*[http://www.zenitel.com/product/tax-2b Additional Documentation on Zenitel.com]
 
[[Category: Turbine Backboxes and accessories]]
 
[[Category: Turbine Backboxes and accessories]]

Latest revision as of 10:24, 28 March 2022

TAX-2B: Plugbox with 10 meter cable

TAX-2b is an Ex-Approved Plugbox & Cable for Headset with PTT.

Highlights

  • 10m cable for EX-areas
  • Compact, rugged plugbox with PTT for Industrial application
  • IP Rating: IP66
  • For use with Headset - AK5850HS
  • Designed for Exigo & Turbine EX explosion-proof intercoms


Connecting TAX-2b Plugbox to TFIX series Intercoms

Connect the wire ferrules on the Plugbox cable to the terminal block according to the pin configuration below. Note that the black (shield) wire is labeled MIC- and the black (main shield) wire is labeled GND.

Connecting TAX-2b Plugbox to TFIX series Intercoms



Connecting TAX-2b Plugbox to TFIX-V2 series Intercoms

Connect the wire ferrules on the Plugbox cable to the connectors according to the pin configuration below. Note that the black (shield) wire is labeled MIC- and the black (main shield) wire is labeled GND.

Connection of Headset AK5850HS and Plugbox TAX-2B on TFIX-V2



Related Information