Actions

Difference between revisions of "Touchless sensor (w/ backbox)"

From Zenitel Wiki

(Configuration on IC-Edge)
Line 40: Line 40:
  
 
=== Configuration on ICX-AlphaCom ===
 
=== Configuration on ICX-AlphaCom ===
 +
 +
[[File:TouchLess ICX.png|thumb|500px|left|Input 1 configured to call number 13 when triggered]]
 +
<br style="clear:both;" />
 +
 +
 
Configuration of Inputs and Direct Access Keys (DAK) are done in [[Users & Stations (AlphaPro)|AlphaPro]]. <br>
 
Configuration of Inputs and Direct Access Keys (DAK) are done in [[Users & Stations (AlphaPro)|AlphaPro]]. <br>
 
Detailed information is found under [[Users & Stations (AlphaPro)#DAK|DAK programming]].
 
Detailed information is found under [[Users & Stations (AlphaPro)#DAK|DAK programming]].
  
 
[[Category:Additional equipment]]
 
[[Category:Additional equipment]]

Revision as of 15:04, 17 March 2021

Touchless sensor, item 2390020100

The Touchless sensor (item 2390020100) is an IR-sensor that connects to Turbine Compact stations and is used to activate calls with gesture recognition instead of pressing the call button.

Highlights

  • Input Voltage: 5V
  • Available contacts: Normally Open & Normally Closed
  • Sensor active time: 0,5 secs
  • Operating distance: 15cm
  • IP66

Connections

Connections are made to the switch using the supplied 5 pin plug.
Correct orientation of the plug is ensured by the connector locating guides.

Color code

  • Red - +5 Volt supply
  • Brown - 0 Volt supply
  • Green - Normally Closed
  • Blue - Common
  • Purple - Normally Open

Typical Application

Touchless sensor - general wiring


Use Case Examples

Touchless sensor wired to Input 1 on a Turbine station:

Touchless sensor - wiring example


Configuration on IC-Edge

To configure the Inputs select Edge Controller > System Configuration > Direct Access Keys.
Select Show/Hide Settings on the station you want to configure:

Input 1 configured to call number 13 when triggered


Configure the Input to Call To a directory number when activated.

More details can be found on Direct Access Key Settings.

Configuration on ICX-AlphaCom

Input 1 configured to call number 13 when triggered



Configuration of Inputs and Direct Access Keys (DAK) are done in AlphaPro.