Revision as of 10:51, 2 November 2017

AlphaCom icon 300px.png

Release State: Released
Release Version: 6.0.3.1
Installation Package: VS-OPC Classic for AlphaCom_Setup_V6.0.3.1.msi

VS-OPC Classic for AlphaCom 6.x.x.x

Important Note about Upgrading from version 5.x.x.x.

The AlphaCom OPC server has now been renamed to VS-OPC Classic for AlphaCom. By default it is now installed in C:\Program Files (x86)\Vingtor Stentofon\VS-OPC Classic for AlphaCom and the Start menu location is Start --> Vingtor Stentofon. This is where the shortcut to OPC Configurator for AlphaCom can be found. It is therefore important to uninstall an AlphaCom OPC server with a version number earlier than 6.x.x.x, before installing this new software.
It is also required to register the server. In the installation directory right-click RegServer.exe and select Run as administrator.

VS-OPC Classic for AlphaCom 6.0.3.1

Upgrades

The OPC server is now based on .NET 4.6.2

Errors corrected

MTN-1180: OPC: hanging OPC server process

In some installations the OPC server would hang or crash. This was solved by upgrading to .NET 4.6.2 and upgrading to the latest Advosol components.

MTN-1183: OPC client cannot connect to OPC server after server restart

When the server computer running the OPC server is restarted (power failure for instance), the OPC client cannot automatically reconnect to the OPC server.This was solved by upgrading to .NET 4.6.2 and upgrading to the latest Advosol components.

MTN-1321: Relay on Turbine not operating from OPC on 12.3.3.2

The mapping of outputs has been changed on AMC-IP software 12.3.3.2. The OPC server is now independent of this mapping and will work with all AMC-IP software versions.

MTN-1322: Turbine extended not supported in OPC server

Turbine Extended has more outputs available than Turbine. These outputs are now also accessible from the OPC server

MTN-1356: The station.releatedto item does not show any info after call transfer

After a call transfer, the station.relatedto now shows the correct information

MTN-1173: In the OPC configurator About tab there is a link to download OPC core components. This link is no longer valid.

The link now connets to a page from where download of OPC core components is possible.

AlphaCom OPC Server 5.x.x.x

For the release notes of AlphaCom OPC Server 5.x.x.x please go to OPC Server - Release Notes