This document provides the release notes for INCA 0.1 with incremental bug fix releases. The release notes for INCA 0.1 describe new features, improvements and issues fixed after the initial release.


Contents

A100G80222.0106 (2008-09-12)

Release: Official, available on request
DIP protocol version 00.04.

System upgrade file:
Image: A100G80222.0106.bin
Checksum: 35131CE0

Errors Corrected

(BZ = Bugzilla reference number)

Simplex audio

In simplex (e.g. remote M-key), the loudspeaker audio was unstable. Improved by turning off the DSP's NLP (Non Linear Processor) in this mode.

Ethernet disconnection issue

If network cable was disconnected and an event (input) occurred immediately after that, the disconnection would not be detected until after about 20 minutes. Fixed.

AlphaCom reconnection attempt

If the AlphaCom didn't have IP station licenses the station would not connect, and neither make an attempt to reconnect. Now it will try to reconnect and will come up when the IP station licenses are installed. (Previous workaround: Restart the IP station or AlphaCom.)

BZ 34: IP sub: Don't work after AMC-IP change

When swapping the AlphaCom AMC boards between two configured with the same IP address (redundancy), the IP station would not reconnect properly. Fixed.

Upgrading made web server password reset

The web server password was reset to default after a software upgrade. Fixed in 01.06. Note that upgrading to 01.06 from an older version may still make the password reset, but later upgrades will not.

IP address string length

IP addresses of maximum length (15 characters XXX.XXX.XXX.XXX) could not be used. Fixed.

Adjusting volume during conversation

Volume adjustment during a conversation often failed.

Upgrade between different IP subnets

Upgrading failed when running the TFTP server on a different subnet than the IP stations.

Functional changes / Enhancement

M-key supported

When pressing remote M-key, audio direction is now set accordingly. Also, with the matrix keyboard testpads, it is posbile to connect an M-key on the substation.

TCP disconnection

Changed behavior upon TCP disconnection. Now the relay output, station LED and any playing tone is reset upon disconnection.

Group call, conference, audio distribution supported

Station can now use the groupcall, simplex conference and audio distribution features.

Full keyboard supported through testpads

A keyboard matrix can be connected through the testpads KEY0-KEY8, as for the IP master station. For specifically designed projects only.

Tone message to play locally-generated tones

Supports tone commands from AlphaCom to generate tones locally in IP station, instead of receiving as audio streams.

Station LED is controlled by AlphaCom

Previously the LED was controlled locally during a conversation. Now it is entirely contolled by AlphaCom messages.


A100G80222.0105 (2007-10-02)

Release: Official, available on request
DIP protocol version 00.02.

System upgrade file:
Image: A100G80222.0105.bin
Checksum: 1E190866

Errors Corrected

Issue 2532: Crash when using non-English characters

The station crashed or had unpredicted behavior when using non-English characters in station name in AlphaPro. If the fault has appeared, a factory reset procedure must be executed, even if the software has been upgraded to 0105.

A100G80222.0104 (2007-09-26)

Release: Official, available on request
DIP protocol version 00.02.

System upgrade file:
Image: A100G80222.0104.bin
Checksum: 8E59E874

Errors Corrected

Status LED blink sequence

The status LED on the PCB didn't blink red-green-green mode when connected but not registered in AlphaCom, as described in documentation sheet.


A100G80222.0103 (2007-09-13)

Release: Official, available on request
DIP protocol version 00.02.

System upgrade file:
Image: A100G80222.0103.bin
Checksum: 84F70D79


A100G80222.0102 (2007-09-13)

Release: Special version, for some boards only
DIP protocol version 00.02.

System upgrade file:
Image: A100G80222.0102.bin
Checksum: A44A8228

Errors Corrected

Issue 3234: Beep-beep tone in loudspeaker

The station plays a beep-beep tone when a key input is pressed without having connection to AlphaCom, for hardware testing. But this tone reappeared in conversations even after AlphaCom connection was restored.

Station reset

There was a weakness causing the station to do an unprovoked reset.

Network problems on some boards

Device-specific fix of network speed for some boards.

Functional changes / Enhancement

Factory reset procedure didn't timeout

When powering the station and key input 1 is active, factory reset state is entered. This state was held until key input 1 was released. Added a 30 second timeout in case key input 1 is held low without the intention to do factory reset.


A100G80222.0101 (2007-06-07)

Release: Official, available on request
DIP protocol version 00.02.

System upgrade file:
Image: A100G80222.0101.bin
Checksum: 3856A856

Errors Corrected

Issue 3150: Click-sounds in loudspeaker with G.711 codec

Click sounds appeared in speaker at about 0.5 sec intervals when using G.711 codec.

Call from AlphaNet or SIP to IP substation

There was a problem dialing in from AlphaNet and SIP.

Web pages minor issues

A few pages were displayed incorrectly.


A100G80222.0100 (2007-03-15)

Release: Official, available on request
DIP protocol version 00.02.

System upgrade file:
Image: A100G80222.0100.bin
Checksum: 8180DE75


Known Issues (Latest release)



Hardware Drivers




A100G80221.0002 (2007-04-20)

Functional changes / Enhancement

Support for 8MB FLASH chip

Support for 8MB Intel FLASH 28F640J3A.


A100G80221.0001 (2007-03-27)

Functional changes / Enhancement

IP station full upgrade support