M100D Release 00.27 (X2014-04-24)

This is still a X release of the M100D software.

M100D Errors Corrected

All previous releases of the M100D failed to parse more than 100 directory numbers, both Alpha and M100, from XML config file to local directory table (although the size of the local directory tables could hold 1000 entries).
This is now corrected, however the max number of directory numbers has been increased to 2000 (both Alpha and M100).

M100D Functional Changes / Enhancements

Increased number of directory entries from 1000 to 2000. This is valid for both Alpha and M100 numbers.

M100D Release 00.26 (X2014-04-02)

This is still a X release of the M100D software.

M100D Errors Corrected

Fixed problem if AlphaCom activated Group Call (AUDIO_M_PATH_SETUP) and did not receive response within 2 sec, due to slow M100 interface, the AMC would resend the request. This made M100D to allocate a second fsm_ind which was never released. This release checks if the second AUDIO_M_PATH_SETUP has the same source msg ref as the already received in the first AUDIO_M_PATH_SETUP and if so, this request is discarded and ignored and hence no new M100D fsm_ind is allocated.
A temporarily fix in the timeout in AMC nvram will also avoid this:
70 &001060 .ex_profile.timeouts.audio_link_timeout = 20 (0x0014) change to 50 (5 sec)

M100D Release 00.25 (X2014-04-01)

This is still a X release of the M100D software.

M100D Errors Corrected

Fixed bug in Group Call from M100.

M100D Release 00.24 (X2014-04-01)

This is still a X release of the M100D software.

M100D Errors Corrected

Fixed bug in Group Call from M100.
Fixed problem if AlphaCom activated Group Call when link was down, Group Call was executed when link was up and M100 stations was connected but AC disconnected and hence M100 stations was connected until Call Timeout.

M100D Release 00.23 (X2014-03-28)

This is still a X release of the M100D software.

M100D Errors Corrected

M100D failed to cancel Group Calls initiated in M100. AC stations did not cancel.

M100D Release 00.21 (X2014-03-21)

This is still a X release of the M100D software.

M100D Errors Corrected

M100D failed to release allocated software resources (M100 communication channel 1..7, real number) after disconnection calls to M100.

M100D Release 00.20 (X2014-03-19)

This is still a X release of the M100D software.

M100D Errors Corrected

When heavy traffic from AlphaCom towards the M100 several of the called M100 stations did not disconnect and where connected "forever". Fixed by major re-write of the disconnect sequence towards the M100.
Fixed problem with link "hanging" when sending F6FAF6FA.....
Made UART hack to wait for only 1 byte and thus speeding up the serial communication.

M100D Release 00.12 (X2012-04-26)

This is still a X release of the M100D software.

M100D Errors Corrected

M100D Web does not pad ~ instead of spaces at end of Alpha text. This version of M100D inserts spaces to fill up complete Alpha text (16 chars).

M100D Functional Changes / Enhancements

M100D Release 00.11 (X2012-03-12)

This is still a X release of the M100D software.

M100D Errors Corrected

M100D Functional Changes / Enhancements

Added support for GET_DEVICE, both receive and reply to AMC. Relates to all previous X releases.

M100D Release 00.10 (X2010-05-28)

This is the first X release of the M100D software. Released to be tested for possible projects in Austria.

M100D Errors Corrected

M100D Functional Changes / Enhancements

Changed/added support for ODIN regarding Group Calls and ordinary calls (timing problems). Relates to all previous X releases.