VSF-Fortitude8 10.1 Release Notes
From Zenitel Wiki
- Previous Release - VSF-Fortitude8 10.0 Release Notes
This document provides the release notes for VSF-Fortitude8 version 10.1 with incremental bug fix releases. The release notes describe new features, improvements and issues fixed after VSF-Fortitude8 version 10.0.x.x.
Compatibility:
|
Release info
Name: VSF-Fortitude8
Description: VSF-Fortitude8 is a firmware for Zenitel devices based on the IMX8 processor.
The firmware is delivered in two different files:
- vsff8-10.1.3.x - Used for standard in-field upgrades
- vsff8-prod-10.1.3.x - Used in production- and recovery upgrades.
Version: 10.1.3.0
Date: 11.11.2026
Status: General Availability
Compatibility: Version 10.1.x.x is compatible with the Zenitel Connect platform only.
VSF-FORTITUDE8 10.1.3.0
Improvements
DS-1916 Recalibrated Automatic Volume Control (AVC) Measurement on ZDD and ZSD
Recalibrated mic level SPL on ZDD-1 and ZSD-1 allowing AVC to adjust loudspeaker levels more naturally based on room noise.
Note: In version 9.5 the reported mic SPL levels were about +10 dB too high. The mic frequency responses were also tuned on these devices.
DS-1879 Acoustic Tuning & Echo Suppression Improvements
Updated acoustic filter profiles for TMIV+ station to minimize resonance, suppress echo artifacts, and deliver clearer speech intelligibility during open-duplex calls.
DS-1870 Acoustic Tuning & Echo Suppression Improvements
Updated acoustic filter profiles for TCIV+ stations to minimize resonance, suppress echo artifacts, and deliver clearer speech intelligibility during open-duplex calls.
Fixed issues
DS-1905 Multitone tone test robustness adjustments
Adjusted thresholds for tone FFT bin magnitude feedback from speaker to mic to reduce false negatives in moderate to high noise.
DS-1903 Security Update
Resolved vulnerabilities related to: CVE-2026-95379 Path traversal in certificate deletion API.
- Action: Upgrade to 10.1.3.0 or later
DS-1902 Security Update
Resolved vulnerabilities related to: CVE-2026-95378 Path traversal in certificate upload.
- Action: Upgrade to 10.1.3.0 or later.
DS-1901 Security Update
Resolved vulnerabilities related to: CVE-2026-95377 OS command injection via DHCP provisioning.
- Action: Upgrade to 9.6.3.0 or later for SIP, IC-Edge and ICX-Alphacom, and 10.1.3.0 or later for Zenitel Connect.
DS-1844 Bottom pixels on TCIS-6 and TCIV-6+ do not scroll with the other text
Bottom pixels on scrolling stations are now correctly updated
DS-1839 Configuring the NTP server over the web now works
Resolved an issue that prevented NTP server settings from being configured through the web interface.