Actions

ZIPS 10.0 - Release notes

From Zenitel Wiki

This document provides the release notes for VSF-Fortitude Audio Only 10.0 with incremental bug fix releases. The release notes describe new features, improvements and issues fixed after VSF-Fortitude Audio Only 9.4.3.1.

Note icon Compatibility:
  • Version 10.0.x.x is supported exclusively on the Zenitel Connect Pro platform.
  • It is not compatible with ICX-AlphaCom, IC-Edge, or deployments operating in SIP mode.


Note icon Software Upgrade:
  • The IMT tool (Intercom Management Tool) is not compatible with device version 10. Software upgrade to version 10 must be done either from the Zenitel Connect Pro server web interface or from the web interface of the device it self.


Release info

Name: VSF-Fortitude Audio Only
Description: VSF-Fortitude Audio Only is a firmware for Zenitel devices based on the IMX8M Nano processor.

The firmware is delivered in two different files:

  • vsff8mn-10.0.3.x - Used for standard in-field upgrades
  • vsff8mn-prod-10.0.3.x - Used in production- and recovery upgrades.

Version: 10.0.3.2
Date: 25.06.2026
Status: General available
Compatibility: Version 10.0.x.x is compatible with the Zenitel Connect Pro platform only.


VSF-FORTITUDE Audio Only 10.0.3.2

Improvements

DS-1720 Disabled SNMP port by default in firewall

The SNMP port is now disabled by default in the firewall on all new and factory-reset devices. Customers who require SNMP must enable it manually in the device configuration before use.

DS-1683 Security Update

Resolved vulnerabilities related to

  • CVE-2025-15467 Stack buffer overflow

Action: Upgrade to 9.5.3.0 or later

DS-321 New Secure Web Stack Support for Zenitel Connect Systems

Support added for new modern and security-hardened web interface to improve cybersecurity compliance. The new interface is served over HTTPS by default.

Important Downgrade Notice: When downgrading from the version 10.x.x.x (or newer) to version 9.x.x.x (or older), the HTTP port must be open prior to downgrade. After downgrading, manually refresh the browser to access the old web interface via HTTP. If the HTTP port was not opened beforehand, a physical factory reset is required to restore device functionality.


Fixed issues

DS-1639 Fixed an issue with GPIO pin on ZIPS speakers did not work when configured as output

GPIO pins on ZIPS speakers configured as output via the Relays/Outputs page would not execute the assigned action. The GPIO output now works as expected in all configuration methods.