Difference between revisions of "TFIX - Installation Solutions"
From Zenitel Wiki
(→Single TFIX with beacon) |
(→Multiple TFIX'es with beacon) |
||
Line 20: | Line 20: | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | == Multiple TFIX'es with | + | == Multiple TFIX'es with external signal device == |
− | Multiple TFIX'es with | + | Multiple TFIX'es with external signal device in the EX zone, where all the controlling equipment is located in the safe zone in closed cabinets in a more convenient placements out in the field. <br/> |
Each cabinet consist of: | Each cabinet consist of: | ||
* 1 Turbine extended kit; TKIE | * 1 Turbine extended kit; TKIE | ||
* 1 Turbine Relay board; TA-10 | * 1 Turbine Relay board; TA-10 | ||
− | * 1 | + | * 1 24VDC or 230VAC PSU for external signal device |
* 1 Flowire unit; FCDC2 | * 1 Flowire unit; FCDC2 | ||
* 1 24VDC Flowire PSU | * 1 24VDC Flowire PSU | ||
Line 34: | Line 34: | ||
---- | ---- | ||
− | Multiple TFIX'es with | + | Multiple TFIX'es with external signal device in the EX zone, where all controlling equipment is located in the server room. <br/> |
For every sixth TFIX with beacon you need: | For every sixth TFIX with beacon you need: | ||
* 1 Turbine compact Kit; [[TKIS-2 VoIP Intercom Module - 1008131020|TKIS-2]] | * 1 Turbine compact Kit; [[TKIS-2 VoIP Intercom Module - 1008131020|TKIS-2]] |
Revision as of 13:51, 29 October 2015
ARTICLE UNDER CONSTRUCTION!!!
Contents
TFIX station with external signal device
In noisy areas a beacon lamp and/or a signal bell/horn can be used to indicate an incoming call or PA announcement.
Single TFIX with external signal device
A single TFIX with external signal device in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.
The cabinet consist of:
- 1 Turbine extended kit; TKIE
- 1 Turbine Relay board; TA-10
- 1 24VDC or 230VAC PSU for signal device
- 1 Flowire unit; FCDC2
- 1 24VDC Flowire PSU
Multiple TFIX'es with external signal device
Multiple TFIX'es with external signal device in the EX zone, where all the controlling equipment is located in the safe zone in closed cabinets in a more convenient placements out in the field.
Each cabinet consist of:
- 1 Turbine extended kit; TKIE
- 1 Turbine Relay board; TA-10
- 1 24VDC or 230VAC PSU for external signal device
- 1 Flowire unit; FCDC2
- 1 24VDC Flowire PSU
Multiple TFIX'es with external signal device in the EX zone, where all controlling equipment is located in the server room.
For every sixth TFIX with beacon you need:
- 1 Turbine compact Kit; TKIS-2
- 1 Multi-relay board; MRBD
- 1 24VDC PSU: for the MRBD
- 1 Flowire unit; FCDC2
- 1 24VDC Flowire PSU
- 6 Relay boxes; IRR-3
- 6 Beacons; BEX24O or BEX230O
- 6 Beacon Power supplies; 24VDC or 230VAC