Difference between revisions of "Station Fault (Event Type)"
From Zenitel Wiki
(→Application) |
(→Fault types) |
||
Line 20: | Line 20: | ||
If Subevent is set to 255, all fault types will be reported. One can use [[%sev]] to read the subevent number. | If Subevent is set to 255, all fault types will be reported. One can use [[%sev]] to read the subevent number. | ||
==Fault types== | ==Fault types== | ||
+ | |||
+ | {| {{table}} | ||
+ | | align="center" style="background:#f0f0f0;"|'''Subevent''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Fault''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Default text from %2.nam''' | ||
+ | |- | ||
+ | | 0||Any amplifier fault||Gen Fault | ||
+ | |- | ||
+ | | 1||Any fault, Channel 1||CH1 Fault | ||
+ | |- | ||
+ | | 2||Any fault, Channel 2||CH2 Fault | ||
+ | |- | ||
+ | | 3|| LET fault, Channel 1||CH1 Let Fault | ||
+ | |- | ||
+ | | 4||LET fault, Channel 2||CH2 Let Fault | ||
+ | |- | ||
+ | | 5||Amplifier shutdown, Channel 1||CH1 Amp shutdown | ||
+ | |- | ||
+ | | 6||Amplifier shutdown, Channel 2||CH2 Amp shutdown | ||
+ | |- | ||
+ | | 7||SLM faults, Channel 1||CH1 Spk.li.fault | ||
+ | |- | ||
+ | | 8||SLM faults, Channel 2||CH2 Spk.li.fault | ||
+ | |- | ||
+ | | 9||Over temperature, Channel 1||CH1 Temp alarm | ||
+ | |- | ||
+ | | 10||Over temperature, Channel 2||CH2 Temp alarm | ||
+ | |- | ||
+ | | 11||Cooling fan fault||Fan fault | ||
+ | |- | ||
+ | | 12||Eth1 fault||ETH1 fault | ||
+ | |- | ||
+ | | 13||Eth2 fault||ETH2 fault | ||
+ | |- | ||
+ | | 14||Software fault||Software fault | ||
+ | |- | ||
+ | | 15||AC power fault||AC fault | ||
+ | |- | ||
+ | | 16||DC power fault||DC fault | ||
+ | |- | ||
+ | | 17||EMBDR-8 missing||EMBDR fault | ||
+ | |- | ||
+ | | 18||MIC fault||MIC fault | ||
+ | |- | ||
+ | | 19||RCO Fault||RCO fault | ||
+ | |- | ||
+ | | 20||RCI Fault||RCI fault | ||
+ | |- | ||
+ | | | ||
+ | | | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
0. Any amplifier fault <br> | 0. Any amplifier fault <br> |
Revision as of 14:44, 12 April 2018
Event description
Event Owner: | Station reporting the fault. |
Event type: | 43 - Station Fault Report |
Subevent: | Fault type, see list below |
When change to ON: | When fault is active. |
When change to OFF: | When fault is gone |
When related to: | Fault description text returned in %2.nam |
If Subevent is set to 255, all fault types will be reported. One can use %sev to read the subevent number.
Fault types
Subevent | Fault | Default text from %2.nam |
0 | Any amplifier fault | Gen Fault |
1 | Any fault, Channel 1 | CH1 Fault |
2 | Any fault, Channel 2 | CH2 Fault |
3 | LET fault, Channel 1 | CH1 Let Fault |
4 | LET fault, Channel 2 | CH2 Let Fault |
5 | Amplifier shutdown, Channel 1 | CH1 Amp shutdown |
6 | Amplifier shutdown, Channel 2 | CH2 Amp shutdown |
7 | SLM faults, Channel 1 | CH1 Spk.li.fault |
8 | SLM faults, Channel 2 | CH2 Spk.li.fault |
9 | Over temperature, Channel 1 | CH1 Temp alarm |
10 | Over temperature, Channel 2 | CH2 Temp alarm |
11 | Cooling fan fault | Fan fault |
12 | Eth1 fault | ETH1 fault |
13 | Eth2 fault | ETH2 fault |
14 | Software fault | Software fault |
15 | AC power fault | AC fault |
16 | DC power fault | DC fault |
17 | EMBDR-8 missing | EMBDR fault |
18 | MIC fault | MIC fault |
19 | RCO Fault | RCO fault |
20 | RCI Fault | RCI fault |
Applications
|