Station errors are by default sent to the [[System log]]. From AlphaPro one can disable this reporting.
 
Station errors are by default sent to the [[System log]]. From AlphaPro one can disable this reporting.
 +
 +
Go to the [[Exchange_%26_System_(AlphaPro)#Logs_and_Errors|Exchange & System > System > Logs and Errors window]]. Under "System Log", uncheck '''Line Error'''.
 +
 +
[[Image:AP LogsAndErrors.png|thumb|500px|The Exchange & System > System > Logs and Errors window|none]]
 +
 +
'''System Log''' It is possible to filter away certain error reportings to the [[System log]]''
 +
 +
* '''Line Error''': Station errors, both analog [[ASLT]] stations and IP Stations. (Station errors will still be reported via [[Faulty Station Line (Event Type)|Event 13 - Faulty Station Line]], and to Supervisor station defined in "Faulty Line" in [[Exchange_%26_System_(AlphaPro)#Faults|Faults]] menu).
 +
* '''Board Error''': Errors on feature boards ([[ASLT]], [[ATLB-12]], [[AGA]], [[ASVP]]) detected by the [[AMC-IP]]
 +
* '''Device/CardCage Error''': Includes the following devices:
 +
** [[RIO]] ([[Device]]s 1 - 64)

Revision as of 15:54, 15 November 2018

AlphaCom icon 300px.png

By default station errors are reported more or less instantly when the AlphaCom server looses connection to an IP Station, or if there is an error on the analog ASLT station line.

Sometimes it could be convenient to delay the reporting, for example if there is maintenance work in the IP network, repatching of cables etc.

This article describes how to disable the default reporting, and how to use customized error reporting using the Event Handler instead.

Disable default Line Error reporting

Reporting to station

Station errors are by default sent to station on physical number 1. From AlphaPro one can disable this reporting.

Go to the Exchange & System > RCI > Faults window, select Fault Line > Change, and delete the MST command in the ON Action field.

The Exchange & System > RCI > Faults window

Disable reporting to System Log

Station errors are by default sent to the System log. From AlphaPro one can disable this reporting.

Go to the Exchange & System > System > Logs and Errors window. Under "System Log", uncheck Line Error.

The Exchange & System > System > Logs and Errors window

System Log It is possible to filter away certain error reportings to the System log

  • Line Error: Station errors, both analog ASLT stations and IP Stations. (Station errors will still be reported via Event 13 - Faulty Station Line, and to Supervisor station defined in "Faulty Line" in Faults menu).
  • Board Error: Errors on feature boards (ASLT, ATLB-12, AGA, ASVP) detected by the AMC-IP
  • Device/CardCage Error: Includes the following devices: