===Remote Control Outputs (RCO)===
 
===Remote Control Outputs (RCO)===
The AlphaCom XE1 does not support any RCO's in the server itself. When remote control outputs are required, please use [[TKIS-2|TKIS-2 kit]] or [[IP-ARIO]].
+
The AlphaCom XE1 does not support any outputs or relays from the server itself. A number of devices can be used to provide such outputs/relays. See [[RCO_-_Remote_Control_Output]]
  
 
=Factory Reset (coldstart)=
 
=Factory Reset (coldstart)=

Revision as of 16:08, 23 January 2019

AlphaCom XE1 Audio Server with HD Voice

Highlights

  • Made to provide critical communication in any environment
  • Supports 552 IP stations
  • Environmental friendly and energy saving - max. 4 W
  • SIM card based software configuration and disaster recovery
  • Fully compatible with any AlphaCom system

Connections

XE1 eth serial.png


Power

The AlphaCom XE1 is powered by 5VDC from 90-240VAC power adapter. The power adapter comes with the XE1 server.

Network

The XE1 server has two RJ-45 ethernet ports for IP communication. Ethernet port 0 (Eth 0) is by default configured as a Management port, allowing connection to the embedded web server (AlphaWeb) and connection of the PC configuration tool AlphaPro. Default IP addresses:

  • Eth0 has IP address 169.254.1.5
  • Eth1 gets IP address from DHCP by default

Serial Ports

The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using serial communication.

  • Serial Port 0: R232 only on an 9-Pin D-sub connector
  • Serial Port 1: RS232, RS422 or RS485 on an RJ45 connector
    • RS232:: Switch 8 on S601 on the AMC-IP board must be set to OFF (default).
    • RS422: Switch 8 on S601 on the AMC-IP board must be set to ON. Jumpers J1 and J2 in position 1-2
    • RS485: Switch 8 on S601 on the AMC-IP board must be set to ON. Jumpers J1 and J2 in position 2-3 (default)
XE1 Serial ports pinout


To access the jumpers J1 and J2, remove the top lid of the XE1 server:

Jumpers J1 and J2 for selection of RS422 or RS485 for Serial Port 1


Remote Control Inputs (RCI)

Connections

There are two inputs for clean contacts on the RCI connectors which can execute programmable functions. Note that the cabinet needs to be opened to get access to these connectors

RCI inputs in an AlphaCom XE1 (top lid removed)


Configuration

In AlphaPro there is an RCI table, where the physical address of the input is entered, along with the desired actions. The physical address is given as device + pin-number.

The RCI table supports up to 140 inputs.

  • For internal RCIs in the AlphaCom XE1, the device address is 65, and the pin number is 1-2.
  • Internal pin number 8 is the temperature alarm (not used in XE1).
  • Mappings for the internal RCI's are autoloaded. Mappings for external RCI's (Slave modules, RIO's or IPARIO) must be manually programmed.
  RCI Type Device/Station physical Number Pin Number
AlphaCom XE1 Device 65 1 - 2

Remote Control Outputs (RCO)

The AlphaCom XE1 does not support any outputs or relays from the server itself. A number of devices can be used to provide such outputs/relays. See RCO_-_Remote_Control_Output

Factory Reset (coldstart)

Performing a cold start of the AMC-IP board will delete all previous programming, load factory default settings and set the IP-address to 169.254.1.5 with mask 255.255.0.0 on Eth0.

Cold start button on AMC-IP board


Cold start procedure

  • Power up while keeping the cold start button pressed.
  • Keep the cold start button pressed at least 2 sec. after power on. The AMC status LED will blink green when the boot is ready.

Cold-start of AMC application only, keep IP setting

  • Power up while keeping the cold start button pressed.
  • After 10 seconds, press the cold start button on the AMC-IP board.
  • Keep the cold start button pressed until the AMC status LED is blinking green.

Modify Factory Default Settings

After cold start the system is set up with a default program and is working without any further programming. To change or add to the default settings, the AlphaPro programming tool must be used.

Other methods of factory default

A factory default can also be achieved in other ways:

  • From AlphaWeb: System Maintenance -> System Recovery -> Load Factory Defaults
  • From AlphaPro: Upload a default AlphaPro database to the exchange

Upgrade

Software upgrade is done from the web interface of the server. To ensure that the system has the latest features, bug fixes and security updates, it is recommended to upgrade to the latest version. See AMC-IP software upgrade

Mounting & Dimensions

The cabinet should be mounted on a shelf or in a 19” rack. It contains one AMC-IP processor board only. The server includes a power board.

Front View


Rear View


Top View