Difference between revisions of "Main Settings - Edge Controller"
From Zenitel Wiki
Line 23: | Line 23: | ||
::- '''Hostname''' (option for network administration) | ::- '''Hostname''' (option for network administration) | ||
− | * '''Disable Reset to Factory default settings using frontboard and I/O | + | * '''Disable Reset to Factory default settings using frontboard and I/O :''' If enabled, factory reset will only be possible from StationWeb. This is disabled by default. |
− | |||
*'''Read IP Address [Turbine only]:''' Check the '''Read IP Address''' box to enable an unregistered station to speak the IP address when the call button is pressed. "Read IP Address" is default enabled. | *'''Read IP Address [Turbine only]:''' Check the '''Read IP Address''' box to enable an unregistered station to speak the IP address when the call button is pressed. "Read IP Address" is default enabled. | ||
− | |||
*'''Enable RSTP [Turbine only]''' (for Industrial & Ex stations): Check the '''Enable RSTP''' box to enable RSTP. RSTP is only required when using redundant networking | *'''Enable RSTP [Turbine only]''' (for Industrial & Ex stations): Check the '''Enable RSTP''' box to enable RSTP. RSTP is only required when using redundant networking | ||
− | |||
*'''Ethernet Speed 10 Mbits/s [Turbine only]''': Enable in some rare cases where it is not convenient to use 100 MBit/s Ethernet speed. Default Ethernet speed is 100 Mbit/s unless switch is configured to 10 Mbit/s. | *'''Ethernet Speed 10 Mbits/s [Turbine only]''': Enable in some rare cases where it is not convenient to use 100 MBit/s Ethernet speed. Default Ethernet speed is 100 Mbit/s unless switch is configured to 10 Mbit/s. | ||
− | |||
− | |||
− | |||
− | |||
Click '''Save''' followed by '''Apply''' to apply the new configuration settings. | Click '''Save''' followed by '''Apply''' to apply the new configuration settings. | ||
[[Category: IC-EDGE Configuration]] | [[Category: IC-EDGE Configuration]] |
Revision as of 15:11, 11 March 2019
This article describes how to configure a Turbine device as an Edge Controller.
You can do all configuration of your devices from the EDGE Controller. There is no need to log on to each device |
- Logging on to the device you will use as the EDGE Controller
- Select Main > Main Settings to access the page for configuring station mode and Network Settings.
Station Mode: Select the mode: Edge Controller
Product Model And Accessory [Turbine only]: Depending on the type of Turbine hardware, there are different Product models and accessories to choose from. Find your model here: Turbine Station Models
IP Settings:
- DHCP – Select this option if the IP station shall receive IP Settings from a DHCP server.
- Static IP – Select this option if the IP station shall use a static IP address. Enter values for:
- - IP-address
- - Subnet-mask
- - Gateway
- - DNS Server 1 (option for network administration)
- - DNS Server 2 (option for network administration)
- - Hostname (option for network administration)
- Disable Reset to Factory default settings using frontboard and I/O : If enabled, factory reset will only be possible from StationWeb. This is disabled by default.
- Read IP Address [Turbine only]: Check the Read IP Address box to enable an unregistered station to speak the IP address when the call button is pressed. "Read IP Address" is default enabled.
- Enable RSTP [Turbine only] (for Industrial & Ex stations): Check the Enable RSTP box to enable RSTP. RSTP is only required when using redundant networking
- Ethernet Speed 10 Mbits/s [Turbine only]: Enable in some rare cases where it is not convenient to use 100 MBit/s Ethernet speed. Default Ethernet speed is 100 Mbit/s unless switch is configured to 10 Mbit/s.
Click Save followed by Apply to apply the new configuration settings.