Difference between revisions of "Main Settings - Edge Controller"
From Zenitel Wiki
Line 24: | Line 24: | ||
* '''Disable Reset to Factory default settings using frontboard and I/O :''' If enabled, factory reset will only be possible from StationWeb. This is disabled by default. | * '''Disable Reset to Factory default settings using frontboard and I/O :''' If enabled, factory reset will only be possible from StationWeb. This is disabled by default. | ||
− | *'''Read IP Address | + | *'''Read IP Address:''' When enabled an unregistered station will speak its IP address when the call button is pressed. "Read IP Address" is default enabled. |
− | *'''Enable RSTP | + | *'''Enable RSTP''' (for Industrial & Ex stations): Check the '''Enable RSTP''' box to enable Rapid Speanning Tree Protocol RSTP. RSTP is only required when using redundant networking |
− | *'''Ethernet Speed 10 Mbits/s | + | *'''Ethernet Speed 10 Mbits/s''': Enable in some rare cases where it is not convenient to use 100 MBit/s Ethernet speed. Default Ethernet speed is 100 Mbit/s unless switch is configured to 10 Mbit/s. |
Click '''Save''' to apply the new configuration settings. | Click '''Save''' to apply the new configuration settings. | ||
[[Category: IC-EDGE Configuration]] | [[Category: IC-EDGE Configuration]] |
Revision as of 15:21, 11 March 2019
This article describes how to configure a Turbine device as an Edge Controller.
|
- Logging on to the device you will use as the Edge Controller
- Select Main > Main Settings to access the page for configuring station mode and Network Settings.
Mode: Select the mode Edge Controller
Product Model And Accessory: Depending on the type of Turbine hardware, there are different Product models and accessories to choose from. Find your model here: Turbine Station Models
IP Settings:
- Static IP – The Edge Controller must be assigned a Static IP address. Enter values for:
- IP-address
- Subnet-mask
- Gateway
- DNS Server 1 (option for network administration)
- DNS Server 2 (option for network administration)
- Hostname (option for network administration)
- Disable Reset to Factory default settings using frontboard and I/O : If enabled, factory reset will only be possible from StationWeb. This is disabled by default.
- Read IP Address: When enabled an unregistered station will speak its IP address when the call button is pressed. "Read IP Address" is default enabled.
- Enable RSTP (for Industrial & Ex stations): Check the Enable RSTP box to enable Rapid Speanning Tree Protocol RSTP. RSTP is only required when using redundant networking
- Ethernet Speed 10 Mbits/s: Enable in some rare cases where it is not convenient to use 100 MBit/s Ethernet speed. Default Ethernet speed is 100 Mbit/s unless switch is configured to 10 Mbit/s.
Click Save to apply the new configuration settings.