Actions

Difference between revisions of "Main Settings - Edge Controller"

From Zenitel Wiki

Line 21: Line 21:
 
** '''IP-address'''
 
** '''IP-address'''
 
** '''Subnet-mask'''
 
** '''Subnet-mask'''
** '''Gateway'''
+
** '''Gateway''': The controller should have a valid Default Gateway address defined.
** '''DNS Server 1''' (option for network administration)
+
** '''DNS Server 1''': (option for network administration)
** '''DNS Server 2''' (option for network administration)
+
** '''DNS Server 2''': (option for network administration)
** '''Hostname''' (option for network administration)
+
** '''Hostname''': (option for network administration)
  
 
* '''Disable Reset to Factory default settings using frontboard and I/O :''' If enabled, factory reset will only be possible from StationWeb. This is disabled by default.  
 
* '''Disable Reset to Factory default settings using frontboard and I/O :''' If enabled, factory reset will only be possible from StationWeb. This is disabled by default.  

Revision as of 15:28, 11 March 2019

Edge-icon.jpg
icon This article is under construction!


This article describes how to configure a Turbine device as an Edge Controller.

Note icon
  • You can do all configuration of your devices from the Edge Controller. There is no need to log on to each device
  • The Edge Controller must be a Turbine device. Turbine video station TCIV or INCA Station cannot be used as an Edge Controller
  • The Edge Controller should always use a Static IP Address, not obtain IP address from a DHCP server


Setting the Edge Controller


Mode: Select the mode Edge Controller

Product Model And Accessory: Depending on the type of Turbine hardware, there are different Product models and accessories to choose from. Find your model here: Turbine Station Models

IP Settings:

  • Static IP – The Edge Controller must be assigned a Static IP address. Enter values for:
    • IP-address
    • Subnet-mask
    • Gateway: The controller should have a valid Default Gateway address defined.
    • DNS Server 1: (option for network administration)
    • DNS Server 2: (option for network administration)
    • Hostname: (option for network administration)
  • Disable Reset to Factory default settings using frontboard and I/O : If enabled, factory reset will only be possible from StationWeb. This is disabled by default.
  • Read IP Address: When enabled an unregistered station will speak its IP address when the call button is pressed. "Read IP Address" is default enabled.
  • Enable RSTP (for Industrial & Ex stations): Check the Enable RSTP box to enable Rapid Speanning Tree Protocol RSTP. RSTP is only required when using redundant networking
  • Ethernet Speed 10 Mbits/s: Enable in some rare cases where it is not convenient to use 100 MBit/s Ethernet speed. Default Ethernet speed is 100 Mbit/s unless switch is configured to 10 Mbit/s.

Click Save to apply the new configuration settings.