Difference between revisions of "Event Trigger w/User Parameter"
From Zenitel Wiki
(13 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
+ | {{AI}} | ||
{| | {| | ||
|- | |- | ||
|width="170pt"|'''Feature''': | |width="170pt"|'''Feature''': | ||
− | | Event Trigger | + | | Event Trigger w/User Parameter |
|- | |- | ||
|'''Default directory number''': || 9535 | |'''Default directory number''': || 9535 | ||
Line 10: | Line 11: | ||
|'''Parameter 1''': || 0-255 = Subevent in the Event Handler | |'''Parameter 1''': || 0-255 = Subevent in the Event Handler | ||
|-valign="top" | |-valign="top" | ||
− | |'''Description''': || Event Trigger feature allowing user-parameter. Can be used to build special functions from the [[Event Handler]]. Many directory numbers can be dialed in sequence as parameter | + | |'''Description''': || Event Trigger feature allowing user-parameter. Can be used to build special functions from the [[Event Handler]]. Many directory numbers can be dialed in sequence as parameter. Each time a directory number is dialed, the [[Event Trigger with parameter (Event Type)|event type 25]] is triggered. Can be used e.g. to build [[Dynamic group call]]. <br><br> |
+ | Note that the "Parameter 1" value must match the subevent value in the event handler. When using several Event Trigger w/User Parameter for different features, they must be separated from each other by using different parameter 1 and subevent. | ||
− | Example: Dial 9535 + 104 + C | + | |
− | * 9535 - | + | '''Example:''' |
− | * 104 - | + | Dial 9535 + 104 + 109 + C. The following events are triggered: |
− | * C-key | + | * 9535: "[[Event Trigger (Event Type)|15 - Event Trigger]]" ON<br> |
+ | :: "[[Start: Event Trigger with parameter (Event Type)|26 - Event Trigger Start w/User parameter]]" ON | ||
+ | * 104: "[[Event Trigger with parameter (Event Type)|25 - Event Trigger with parameter]]" ON | ||
+ | * 109: "[[Event Trigger with parameter (Event Type)|25 - Event Trigger with parameter]]" ON | ||
+ | * C-key: "[[Event Trigger (Event Type)|15 - Event Trigger]]" OFF | ||
|} | |} | ||
[[AlphaCom Feature List|Back to feature list]] | [[AlphaCom Feature List|Back to feature list]] |
Latest revision as of 08:38, 8 October 2019
Feature: | Event Trigger w/User Parameter |
Default directory number: | 9535 |
Feature number: | 95 |
Parameter 1: | 0-255 = Subevent in the Event Handler |
Description: | Event Trigger feature allowing user-parameter. Can be used to build special functions from the Event Handler. Many directory numbers can be dialed in sequence as parameter. Each time a directory number is dialed, the event type 25 is triggered. Can be used e.g. to build Dynamic group call. Note that the "Parameter 1" value must match the subevent value in the event handler. When using several Event Trigger w/User Parameter for different features, they must be separated from each other by using different parameter 1 and subevent.
|