Difference between revisions of "Dynamic group call"
From Zenitel Wiki
Line 25: | Line 25: | ||
In [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|Exchange and System -> Events]], press Insert and create the following events: | In [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|Exchange and System -> Events]], press Insert and create the following events: | ||
+ | |||
+ | DynGrp Event1.PNG | ||
IF %chg(1,0) | IF %chg(1,0) | ||
Line 37: | Line 39: | ||
ENDIF | ENDIF | ||
+ | DynGrp Event2.PNG | ||
+ | |||
+ | IND %1.phy %1.dak(I%2.dir) 2 1 ON | ||
+ | $GRM L%2.dir L%1.exp U1 | ||
+ | IF %op(%2.dir,=,9535) | ||
+ | $DISCON_ST L%1.dir 0 | ||
+ | IND %1.phy %1.dak(I%2.dir) 2 1 OFF | ||
+ | PAUSE | ||
+ | PAUSE | ||
+ | PAUSE | ||
+ | $DD L%1.dir L%1.exp | ||
+ | |||
+ | |||
+ | |||
+ | DynGrp Event3.PNG | ||
+ | |||
+ | IF %op(%2.dir,=,%1.exp) | ||
+ | IF %chg(1,0) | ||
+ | $ST L%1.dir W0 L%1.exp | ||
+ | stop | ||
+ | ENDIF | ||
+ | IND %1.phy 0 0 0 OFF | ||
+ | ENDIF | ||
+ | DynGrp Event4.PNG | ||
+ | IF %op(%2.dir,=,%1.exp) | ||
+ | IND %1.phy 0 0 0 OFF | ||
+ | ENDIF | ||
[[Category: Applications]] | [[Category: Applications]] | ||
[[Category: Control Room Applications]] | [[Category: Control Room Applications]] |
Revision as of 12:03, 27 May 2021
Operation
- Press a dedicated "Group Configursation" DAK key. The red led in key starts flashing, and the Dynamic Group is emptied.
- Select stations or local groups to be included by pressing the associated DAK keys. A steady green led in the keys indicates that the stations/groups are included
- Press the "Group Configuration" button again, and the group call is activated (the ding-dong chime is played). Pressing the `M`-key opens the microphone.
- The green leds continue to be lit during the group call
- Cancel the group call by pressing the `C`-key. The green LEDs are turned off.
For best performance it is recommended to use CRM V station or ECPIR-3P panel, as these devices have buttons with LEDs showing status.
Software requirements
- ICX: Any version
- AlphaCom: 13.0.3.0 or later
Configuration
- Assign directory number 9535 to DAK 1 of the operator station. This is the Group Configuration button. Directory number 9535 is included by default.
DynGrp DAK.PNG
- Each operator station is assigned its own Dynamic Group Call by entering the Dynamic Group Call number in the User Defined Parameter (%1.EXP) field of the operator.
- Include operator stations in UDP group 1. Name the UDP group e.g. "Operators".
DynGrp UDP.PNG
Event Handler configuration
In AlphaPro, go to Exchange and System -> Events, press Insert and create the following events:
DynGrp Event1.PNG
IF %chg(1,0) IND %1.phy 0 0 0 OFF $GRM LV L%1.exp U3 IND %1.phy %1.dak(I%2.dir) 1 3 ON ENDIF
IF %chg(0,1) IND %1.phy %1.dak(I%2.dir) 1 3 ON $ST L%1.dir W10 L%1.exp ENDIF
DynGrp Event2.PNG
IND %1.phy %1.dak(I%2.dir) 2 1 ON $GRM L%2.dir L%1.exp U1 IF %op(%2.dir,=,9535) $DISCON_ST L%1.dir 0 IND %1.phy %1.dak(I%2.dir) 2 1 OFF PAUSE PAUSE PAUSE $DD L%1.dir L%1.exp
DynGrp Event3.PNG
IF %op(%2.dir,=,%1.exp) IF %chg(1,0) $ST L%1.dir W0 L%1.exp stop ENDIF IND %1.phy 0 0 0 OFF ENDIF
DynGrp Event4.PNG
IF %op(%2.dir,=,%1.exp) IND %1.phy 0 0 0 OFF ENDIF