Actions

Difference between revisions of "Dynamic group call"

From Zenitel Wiki

Line 25: Line 25:
  
 
In [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|Exchange and System -> Events]], press Insert and create the following events:
 
In [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|Exchange and System -> Events]], press Insert and create the following events:
 +
 +
DynGrp Event1.PNG
  
 
IF %chg(1,0)
 
IF %chg(1,0)
Line 37: Line 39:
 
ENDIF
 
ENDIF
  
 +
DynGrp Event2.PNG
 +
 +
IND %1.phy %1.dak(I%2.dir) 2 1 ON
 +
$GRM L%2.dir L%1.exp U1
 +
IF %op(%2.dir,=,9535)
 +
$DISCON_ST L%1.dir 0
 +
IND %1.phy %1.dak(I%2.dir) 2 1 OFF
 +
PAUSE
 +
PAUSE
 +
PAUSE
 +
$DD L%1.dir L%1.exp
 +
 +
 +
 +
DynGrp Event3.PNG
 +
 +
IF %op(%2.dir,=,%1.exp)
 +
IF %chg(1,0)
 +
$ST L%1.dir W0 L%1.exp
 +
stop
 +
ENDIF
 +
IND %1.phy 0 0 0 OFF
 +
ENDIF
  
  
 +
DynGrp Event4.PNG
  
 +
IF %op(%2.dir,=,%1.exp)
 +
IND %1.phy 0 0 0 OFF
 +
ENDIF
  
 
[[Category: Applications]]
 
[[Category: Applications]]
 
[[Category: Control Room Applications]]
 
[[Category: Control Room Applications]]

Revision as of 12:03, 27 May 2021

AlphaCom icon 300px.png

Operation

  • Press a dedicated "Group Configursation" DAK key. The red led in key starts flashing, and the Dynamic Group is emptied.
  • Select stations or local groups to be included by pressing the associated DAK keys. A steady green led in the keys indicates that the stations/groups are included
  • Press the "Group Configuration" button again, and the group call is activated (the ding-dong chime is played). Pressing the `M`-key opens the microphone.
  • The green leds continue to be lit during the group call
  • Cancel the group call by pressing the `C`-key. The green LEDs are turned off.

For best performance it is recommended to use CRM V station or ECPIR-3P panel, as these devices have buttons with LEDs showing status.

Software requirements

  • ICX: Any version
  • AlphaCom: 13.0.3.0 or later

Configuration

  • Assign directory number 9535 to DAK 1 of the operator station. This is the Group Configuration button. Directory number 9535 is included by default.

DynGrp DAK.PNG

  • Each operator station is assigned its own Dynamic Group Call by entering the Dynamic Group Call number in the User Defined Parameter (%1.EXP) field of the operator.
  • Include operator stations in UDP group 1. Name the UDP group e.g. "Operators".

DynGrp UDP.PNG

Event Handler configuration

In AlphaPro, go to Exchange and System -> Events, press Insert and create the following events:

DynGrp Event1.PNG

IF %chg(1,0) IND %1.phy 0 0 0 OFF $GRM LV L%1.exp U3 IND %1.phy %1.dak(I%2.dir) 1 3 ON ENDIF

IF %chg(0,1) IND %1.phy %1.dak(I%2.dir) 1 3 ON $ST L%1.dir W10 L%1.exp ENDIF

DynGrp Event2.PNG

IND %1.phy %1.dak(I%2.dir) 2 1 ON $GRM L%2.dir L%1.exp U1 IF %op(%2.dir,=,9535) $DISCON_ST L%1.dir 0 IND %1.phy %1.dak(I%2.dir) 2 1 OFF PAUSE PAUSE PAUSE $DD L%1.dir L%1.exp


DynGrp Event3.PNG

IF %op(%2.dir,=,%1.exp) IF %chg(1,0) $ST L%1.dir W0 L%1.exp stop ENDIF IND %1.phy 0 0 0 OFF ENDIF


DynGrp Event4.PNG

IF %op(%2.dir,=,%1.exp) IND %1.phy 0 0 0 OFF ENDIF