Difference between revisions of "Door Opening using Dummy Number (Event Handler)"
From Zenitel Wiki
Line 29: | Line 29: | ||
[[Category:AlphaCom Applications]] | [[Category:AlphaCom Applications]] | ||
[[Category:ICX-AlphaCom Applications]] | [[Category:ICX-AlphaCom Applications]] | ||
+ | [[Category:Applications using Event Handler]] |
Latest revision as of 10:14, 8 July 2022
Situation
Some gates are not equipped with door stations, but the operator should use the same Door opening procedure to open the door.
Solution
When the operator gets a signal that there is someone at the door he should dial a 'dummy' number, then press digit 6 to operate a relay output (i.e. a RCO). In the example below any station can dial 9545 + 6 to trigger RCO 4 for 2 seconds, and disconnect with success-tone. Use the two-step event trigger, feature 105.
Programming
In AlphaPro, Directory & Features, press "Insert" to create a directory number, feature 105, for each door. Directory number 9545 is included by default.
In AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:
Action commands:
RCO 4 ON 20 $DISCON_ST L%1.dir U2
Subevent 6: Digit 6 When Change to ON: When the digit is pressed (not released) RCO 4 ON 20: Pulse RCO 4 for 2.0 seconds $DISCON_ST L%1.dir U2: Disconnect the station with successtone