The TA-23 handset comes with a Push-To-Talk (PTT) button and 3.5-meter long cable.
 +
 
 +
==Highlights==
 +
 
 +
*Rugged handset for Industrial application
 +
*PTT-key for simplex operation in extremely noisy environments
 +
*Noise-cancelling microphone
 +
*High quality digital background noise reduction
 +
*HD-voice compatible
 +
*Designed for Turbine Industrial Intercoms
 +
*Can be added to TCIS series intercoms from Firmware 4.9.3.2
 +
 
 +
 
 +
[[File:TA-23 Side.png|right|250px]]
 +
 
 +
==Connecting the TA-23 handset to the TFIE station==
 +
 
 +
*[[Open the TFIE/TFIX Enclosure|Open the TFIE Enclosure]]
 +
*Plug the IDC connectors of the Handset cable into the [[Turbine Extended series board connectors|J8 terminal block]] according to the pin configuration below.
 +
 
 +
[[File:TA-23 Connections 1.PNG|thumb|left|350px|TA-23 Handset Connection on 9-Pin Terminal J8]]
 +
<br style="clear:both;" />
  
The TA-23 handset comes with a Push-To-Talk (PTT) button and 3.5-meter long cable.
 
  
===<u>Highlights</u>===
+
===Configuration===
* Rugged handset for Industrial application
+
* [[Logging into an Zenitel IP Device|Log in to the station web interface]]
* PTT-key for simplex operation in extremely noisy environments
+
* Navigate to '''Audio Settings'''.
* Noise-cancelling microphone
+
* Set "Accessories" to "'''Handset'''"
* High quality digital background noise reduction*
+
* Reboot the station.
* HD-voice compatible*
+
[[File:TFIE Handset.PNG|thumb|left|700px|TA-23 Handset accessory setting]]
* IP Rating: IP66
 
* Designed for Turbine Industrial Intercoms
 
*when used with Turbine Industrial Intercoms
 
[[File:1008140230.PNG|left|400px]]
 
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
===<u>Connecting TA-23 to TFIE</u>===
+
===Handset operation===
* [[Open the TFIE/TFIX Enclosure]]
+
[[File:TFIE SpeakerButton.PNG|thumb|200px|Toggle Button in the TFIE-1 station]]
* Plug the IDC connectors of the Handset cable into the [[Turbine Extended Board Connectors|J8 terminal block]] according to the pin configuration below.
+
*When "Accessory" is set to "'''Handset'''" the station is by default in loudspeaking mode, i.e. the audio is routed to the speaker and microphone of the front panel of the TFIE station. Audio is also routed to the handset speaker, but the handset microphone is disabled.
 +
*When a call is received, handset mode is activated by pressing the PTT button in the handset. The audio will then be routed to the handset, and the loudspeaker and the microphone in the front panel is muted.
 +
*When the TFIE station returns to idle, e.g. when a call is ended, the station will automatically return to loudspeaking mode.
 +
*In stations with '''Toggle''' button ([[TFIE-1]] only), one can also use this button to activate the handset. The button lets you toggle between loudspeaking and handset mode. The LED in the toggle button shows the status:
 +
**Green LED = Loudspeaking mode
 +
**Red LED = Handset mode
 +
 
 +
==Connecting TA-23 to a TCIS series Intercom==
 +
 
 +
*Modify the plastic housing to access the Microphone terminals
 +
*Connect the handset cable as shown below
  
[[File:TA-23 Connections 1.PNG|thumb|left|500px|TA-23 Handset Connection on 9-Pin Terminal J8]]
+
[[File:Ta23 TCIS.png|alt=|left|thumb|653x653px]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
===<u>Dimensions</u>===
+
=== Configuration ===
<gallery widths=150px heights=300px perrow=3>
+
 
 +
* [[Logging into an Zenitel IP Device|Log in to the station web interface]]
 +
* Enable '''Advanced Configuration''' Mode
 +
* Navigate to the '''Audio settings'''
 +
* In the '''Audio Inputs''' section set the "Internal Microphone" to '''I/O Pin A->D Switch (until call-end)''', and select Pin number for the PTT signal. See also [[Audio_Settings_(Devices)#Audio_Inputs]].
 +
 
 +
=== Handset Operation ===
 +
To enable the handset, simply press the PTT button on the handset.  The handset will remain enabled for the duration of the call.
 +
 
 +
==Dimensions==
 +
<gallery widths="150px" heights="300px" perrow="3">
 
File:TA-23 Dimensions 1.PNG
 
File:TA-23 Dimensions 1.PNG
 
File:TA-23 Dimensions 2.PNG
 
File:TA-23 Dimensions 2.PNG
Line 30: Line 66:
 
</gallery>
 
</gallery>
  
<gallery widths=200px heights=175px perrow=2>
+
<gallery widths="200px" heights="175px" perrow="2">
 
File:TA-23 Dimensions 4.PNG
 
File:TA-23 Dimensions 4.PNG
 
File:TA-23 Dimensions 5.PNG
 
File:TA-23 Dimensions 5.PNG
 
</gallery>
 
</gallery>
  
===<u>[http://www.zenitel.com/product/ta-23 Additional Documentation on Zenitel.com]</u>===
+
 
 +
==Related Information==
 +
 
 +
*[http://www.zenitel.com/product/ta-23 Additional Documentation on Zenitel.com]
  
 
[[Category: Turbine Backboxes and accessories]]
 
[[Category: Turbine Backboxes and accessories]]

Latest revision as of 11:23, 5 September 2024

APS.png
The TA-23 handset

The TA-23 handset comes with a Push-To-Talk (PTT) button and 3.5-meter long cable.

Highlights

  • Rugged handset for Industrial application
  • PTT-key for simplex operation in extremely noisy environments
  • Noise-cancelling microphone
  • High quality digital background noise reduction
  • HD-voice compatible
  • Designed for Turbine Industrial Intercoms
  • Can be added to TCIS series intercoms from Firmware 4.9.3.2


TA-23 Side.png

Connecting the TA-23 handset to the TFIE station

TA-23 Handset Connection on 9-Pin Terminal J8



Configuration

TA-23 Handset accessory setting


Handset operation

Toggle Button in the TFIE-1 station
  • When "Accessory" is set to "Handset" the station is by default in loudspeaking mode, i.e. the audio is routed to the speaker and microphone of the front panel of the TFIE station. Audio is also routed to the handset speaker, but the handset microphone is disabled.
  • When a call is received, handset mode is activated by pressing the PTT button in the handset. The audio will then be routed to the handset, and the loudspeaker and the microphone in the front panel is muted.
  • When the TFIE station returns to idle, e.g. when a call is ended, the station will automatically return to loudspeaking mode.
  • In stations with Toggle button (TFIE-1 only), one can also use this button to activate the handset. The button lets you toggle between loudspeaking and handset mode. The LED in the toggle button shows the status:
    • Green LED = Loudspeaking mode
    • Red LED = Handset mode

Connecting TA-23 to a TCIS series Intercom

  • Modify the plastic housing to access the Microphone terminals
  • Connect the handset cable as shown below


Configuration

Handset Operation

To enable the handset, simply press the PTT button on the handset. The handset will remain enabled for the duration of the call.