Difference between revisions of "%prci"
From Zenitel Wiki
(11 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
− | {{ | + | {{AI}} |
− | The '''%prci''' macro is used in the [[Event Handler]] to check state of a physical input on | + | The '''%prci''' macro is used in the [[Event Handler]] to check state of a physical input on a Zenitel IP Device. |
− | + | ==Syntax== | |
'''%prci(station,input_no)''' | '''%prci(station,input_no)''' | ||
− | Return 1 | + | Return 1 (active) or 0 (not active) state of a physical input |
* station: Physical number 1 - 552 | * station: Physical number 1 - 552 | ||
* input_no: Input number 1 - 8 | * input_no: Input number 1 - 8 | ||
− | + | ==Examples== | |
− | %prci(5,1) | + | %prci(5,1) - ''Return state of input 1 on station 5'' |
+ | |||
+ | == Notes == | ||
+ | One can use the [[Faulty Station Line (Event Type)|Faulty Station Line - OFF]] together with %prci to read the status of the inputs when a device registers to the ICX-AlphaCom. However, one have to insert a small delay ([[SET TIMER|$ST]]) of approx. 5 seconds from the device registers to the inputs are read. | ||
+ | |||
+ | |||
+ | |||
Back to [[Event_Handler#List_of_context_parameters]]. | Back to [[Event_Handler#List_of_context_parameters]]. |
Latest revision as of 09:30, 18 November 2024
The %prci macro is used in the Event Handler to check state of a physical input on a Zenitel IP Device.
Syntax
%prci(station,input_no)
Return 1 (active) or 0 (not active) state of a physical input
- station: Physical number 1 - 552
- input_no: Input number 1 - 8
Examples
%prci(5,1) - Return state of input 1 on station 5
Notes
One can use the Faulty Station Line - OFF together with %prci to read the status of the inputs when a device registers to the ICX-AlphaCom. However, one have to insert a small delay ($ST) of approx. 5 seconds from the device registers to the inputs are read.