Actions

Difference between revisions of "PAR RING"

From Zenitel Wiki

Line 21: Line 21:
 
|}
 
|}
  
 
+
[[Category: ACDP messages]]
 
[[AlphaNet_Data_Protocol#Station_Connect_Operations|Back to AlphaNet message list]]
 
[[AlphaNet_Data_Protocol#Station_Connect_Operations|Back to AlphaNet message list]]

Revision as of 21:26, 17 December 2007

PAR_RING 0x0098 152 AMC 10.22
$PAR_RING L104 L105 Include 105 in incoming call ringing on 104
$PAR_RING %1.ref L105 Include 105 in incoming call ringing on event owner
Add a Parallel Ringer station to a call in ringing state. Most useful to be used as an Event Handler action in Private_Ringing_mode_(Event_Type).
1 NET_OBJ_REF Station receiving call in private ringing mode
2 NET_OBJ_REF Station(s) to include in Parallel ringing.

Either a single station, or reference to a group of stations. Max 10 stations can be include in total for parallel ringing for call

Response: COMMAND_RESPONSE

Back to AlphaNet message list