==Calling Through Loudspeaker with Answer at Called Speaker==
+
==Calling Through Loudspeaker, Answer in Called Speaker==
[[Image:FIG MADR 1 1.JPG|thumb|350px|Figure 1.1 Calling Through Loudspeaker with Answer at Called Speaker]]
+
[[Image:FIG MADR 1 1.png|thumb|350px|Figure 1.1 Calling Through Loudspeaker, Answer in Called Speaker]]
 +
This feature enables calling through loudspeaker with answer through the same speaker.
  
===Feature Description===
+
Calling is done by dialling the directory number of the loudspeaker. Press M-key to speak, release to listen. The loudspeaker functions as both loudspeaker and microphone. Cancel the conversation by pressing the C-key.
The AlphaCom can distribute audio through separate loudspeakers with the possibility of answering at the called speaker. When loudspeakers without
+
 
amplification are used, there must not be more than 20 such loudspeakers in one system.  
+
Group call, audio program and alarm messages will also be distributed.
  
 
===Equipment List===
 
===Equipment List===
* AlphaCom System with desired station range
+
* Microphone Amplifier Board Dynamic with Relay MADR, item 1009960100
* Additional loudspeakers
+
* 20-63 Ohm loudspeaker, e.g. item VML-1520 (20 ohm/15W)
* Power Distribution Board PDB 1009970100 (This Board is only required in an E26 installation. E7 and E20 has +24VDC outputs.)
+
* [[Power Distribution Board|Power Distribution Board PDB, item 1009970100]] (required in AlphaCom XE26 only) to power the MADR. See also [[Powering Additional Equipment]]
* Microphone Amplifier Board Dynamic with Relay MADR 1009960100
+
 
In particularly noisy environments, the MADR board should be placed close to the loudspeaker. A MRBD board is then connected between the RCO output and the MADR board input. A local supply of 24 V to the relay on the MADR is needed.
+
In particularly noisy environments, the MADR board should be placed close to the loudspeaker. A [[MRBD|MRBD board]] is then connected between the RCO output and the MADR board input. A local supply of 24 V to the relay on the MADR is needed.
* PC with AlphaPro program and cable for connection to the AlphaCom exchange
 
  
 
===Installation===
 
===Installation===
 +
* Fasten the MADR board onto one of the mounting rails on the distribution field
 +
* Supply the board with 24 V and 0 V (GND) from the Power Distribution Board
 +
* Connect the wires according to Figure 1.1 Calling through loudspeaker with answer in called speaker
 +
* Set all [[MADR_-_Microphone_Amplifier_for_Dynamic_Microphone#Connectors_and_Switches|switches]] (S1-S4) in position 2-3.
 +
* Adjust the sensitivity of the microphone on the MADR board
  
====Installing the Power Distribution Board====
+
===Programming===
* See [[PDB - Power Distribution Board]]
+
The voice direction is switched with the M-key on the calling station. The M-key controls a [[RCO - Set Remote Control Output|RCO command]], which operates a relay on the MADR board.
If a PDB board is already installed, you need not switch off the entire exchange. Just unplug the connector on the PDB board supplying power from
 
the exchange.
 
'''''Caution'''''
 
Do not extend power cables from the PDB outside the exchange rack environment.
 
Use local power for remote installation of equipment.
 
  
====Installing the Microphone Amplifier Board MADR====
+
How to configure the relay operation:
* Fasten the MADR board onto one of the mounting rails on the distribution field.
+
* In [[Users_%26_Stations_%28AlphaPro%29|Users & Stations]] select the MADR directory number in the list box, and press the button 'Events'. 'Insert' a new event with the following attributes:
* Supply the board with 24 V and 0 V (GND) from the Power Distribution Board.
+
[[Image:FIG MADR 1 2.JPG|thumb|350px|Event to control the voice direction]]
* Connect the wires according to Figure 15-6 Calling through loudspeaker with answer in called speaker
 
* Set the [[MADR_-_Microphone_Amplifier_for_Dynamic_Microphone#Connectors_and_Switches|switches]] in the correct positions.
 
* After the programming has been done, adjust the sensitivity of the microphone on the MADR board
 
<br/>
 
 
<br/>
 
<br/>
 +
{|
 +
|-
 +
|width="100pt"|'''Event Owner''':
 +
|width="300pt"|The MADR directory number
 +
|-
 +
|'''Event type''': || [[Audio (Event Type)|1 - Audio]]
 +
|-
 +
|'''Subevent''': || 126 (Press 'Details' to select which types of audio. 126 means all types of audio)
 +
|-
 +
|'''When change to:''' || ON or OFF
 +
|-
 +
|'''When related to''': || (not used)
 +
|-
 +
|'''Action''': || RCO 10
 +
|-
 +
|}
 +
RCO 10 is used as an example. Use the RCO number you have assigned to the MADR physical connection.
 +
 +
<br style="clear:both;" />
  
 
==Calling Through Loudspeaker with Answer in Separate Microphone==
 
==Calling Through Loudspeaker with Answer in Separate Microphone==
[[Image:MADR 2.JPG|thumb|350px|Figure 2.1 Calling Through Loudspeaker with Answer in Separate Microphone]]
+
[[Image:FIG MADR 2 1.png|thumb|350px|Figure 2.1 Calling Through Loudspeaker with Answer in Separate Microphone]]
  
 
===Feature Description===
 
===Feature Description===
The AlphaCom can distribute audio through loudspeakers with the possibility to answer in the separate electret or dynamic microphones. When loudspeakers without amplification are used, there must not be more than 20 such loudspeakers in one system.
+
The AlphaCom can distribute audio through loudspeakers with the possibility to answer in the separate electret or dynamic microphones.
  
 
===Equipment List===
 
===Equipment List===
* AlphaCom System with desired station range
+
* Microphone Amplifier Board Dynamic with Relay MADR, item 1009960100
* Additional loudspeakers and dynamic /electret microphones
+
* 20-63 Ohm loudspeaker, e.g. item VML-1520 (20 ohm/15W)
* Microphone Amplifier Board Dynamic with Relay MADR 1009960100
+
* [[Power Distribution Board|Power Distribution Board PDB, item 1009970100]] (required in AlphaCom XE26 only) to power the MADR. See also [[Powering Additional Equipment]]
* Power Distribution Board PDB 1009970100 (This Board is only required in an E26 installation. E7 and E20 has +24VDC outputs.)
+
* Additional dynamic or electret microphone
  
 
===Installation===
 
===Installation===
 
====Installing the Power Distribution Board====
 
* See [[PDB - Power Distribution Board]]
 
If a PDB board is already installed, you need not switch off the entire exchange. Just unplug the connector on the PDB board supplying power from
 
the exchange.
 
'''''Caution'''''
 
Do not extend power cables from the PDB outside the exchange rack environment.
 
Use local power for remote installation of equipment.
 
 
====Installing the Microphone Amplifier Board MADR====
 
 
* Place the MADR board near the microphone.
 
* Place the MADR board near the microphone.
 
* Connect the wires according to Figure 2.1.
 
* Connect the wires according to Figure 2.1.
* Set the switches in the correct positions.
+
* Set all [[MADR_-_Microphone_Amplifier_for_Dynamic_Microphone#Connectors_and_Switches|switches]] (S1-S4) in position 2-3.
 
* Adjust the sensitivity of the microphone on the MADR board.
 
* Adjust the sensitivity of the microphone on the MADR board.
 
It is possible to place the MADR board on one of the mounting rails in the connection field of the exchange. Then you must run a screened cable from the microphone to the MADR board and run the GND wire to exchange GND on the Subscriber connection board.
 
It is possible to place the MADR board on one of the mounting rails in the connection field of the exchange. Then you must run a screened cable from the microphone to the MADR board and run the GND wire to exchange GND on the Subscriber connection board.
  
===Additional Information===
+
===Programming===
 
* No programming in necessary to use this application. We do however recommend that you program the physical connection for the PA system as a substation.
 
* No programming in necessary to use this application. We do however recommend that you program the physical connection for the PA system as a substation.
 +
 +
===Additional information===
 +
If an electret microphone is used, the MADR board has to be modified.
 
<br/>
 
<br/>
 
<br/>
 
<br/>
  
==Amplified Calling Through Loudspeaker without Answer Option==
+
=Related articles=
[[Image:MADR 3.JPG|thumb|350px|Figure 3.1 Amplified Calling Through Loudspeaker without Answer Option]]
+
* [[MADR - Microphone Amplifier for Dynamic Microphone]]
 
+
* [[WK20 - Applications]]
===Feature Description===
 
You use a loudspeaker for voice distribution of incoming calls. You may also choose to have distribution of group calls and audio programs through the loudspeaker. Additional indication of incoming calls may be connected.
 
 
 
===Equipment List===
 
* AlphaCom System with desired station range
 
* Additional loudspeakers
 
* Filter Board with Speech Adapter FBSAR 10099505000
 
* Power Distribution Board PDB 1009970100 (This Board is only required in an E26 installation. E7 and E20 has +24VDC outputs.)
 
* Power Amplifier WK1000614100
 
* Mounting box
 
* Local power supply for the Power Amplifier
 
* PC with AlphaPro program and cable for connection to the AlphaCom exchange
 
 
 
===Installation===
 
 
 
====Installing the Power Distribution Board====
 
* See [[PDB - Power Distribution Board]]
 
If a PDB board is already installed, you need not switch off the entire exchange. Just unplug the connector on the PDB board supplying power from
 
the exchange.
 
'''''CAUTION'''''
 
Do not extend power cables from the PDB outside the exchange rack environment.
 
Use local power for remote installation of equipment.
 
 
 
====Installing the FBSAR board====
 
* Fasten the FBSAR board onto one of the mounting rails on the distribution field.
 
* Supply the board with 24 V and 0 V (GND) from the Power Distribution Board. Use an 1-pair ordinary installation cable for this purpose. The cable is not supplied with the board.
 
* Run the wires according to Figure 3.1 Amplified Calling through loudspeaker without answer option. Audio and RCO output connections are done from the Subscriber Connection board.
 
* Make sure the switches are in the correct positions.
 
  
====Installing the Power Amplifier====
+
[[Category:Additional equipment]]
* Mount the board in a mounting box near the amplified loudspeaker
 
* Install a local power supply
 
* Connect the cables according to Figure 3.1 Amplified Calling through loudspeaker without answer option
 

Latest revision as of 13:01, 3 November 2016

Calling Through Loudspeaker, Answer in Called Speaker

Figure 1.1 Calling Through Loudspeaker, Answer in Called Speaker

This feature enables calling through loudspeaker with answer through the same speaker.

Calling is done by dialling the directory number of the loudspeaker. Press M-key to speak, release to listen. The loudspeaker functions as both loudspeaker and microphone. Cancel the conversation by pressing the C-key.

Group call, audio program and alarm messages will also be distributed.

Equipment List

In particularly noisy environments, the MADR board should be placed close to the loudspeaker. A MRBD board is then connected between the RCO output and the MADR board input. A local supply of 24 V to the relay on the MADR is needed.

Installation

  • Fasten the MADR board onto one of the mounting rails on the distribution field
  • Supply the board with 24 V and 0 V (GND) from the Power Distribution Board
  • Connect the wires according to Figure 1.1 Calling through loudspeaker with answer in called speaker
  • Set all switches (S1-S4) in position 2-3.
  • Adjust the sensitivity of the microphone on the MADR board

Programming

The voice direction is switched with the M-key on the calling station. The M-key controls a RCO command, which operates a relay on the MADR board.

How to configure the relay operation:

  • In Users & Stations select the MADR directory number in the list box, and press the button 'Events'. 'Insert' a new event with the following attributes:
Event to control the voice direction


Event Owner: The MADR directory number
Event type: 1 - Audio
Subevent: 126 (Press 'Details' to select which types of audio. 126 means all types of audio)
When change to: ON or OFF
When related to: (not used)
Action: RCO 10

RCO 10 is used as an example. Use the RCO number you have assigned to the MADR physical connection.


Calling Through Loudspeaker with Answer in Separate Microphone

Figure 2.1 Calling Through Loudspeaker with Answer in Separate Microphone

Feature Description

The AlphaCom can distribute audio through loudspeakers with the possibility to answer in the separate electret or dynamic microphones.

Equipment List

Installation

  • Place the MADR board near the microphone.
  • Connect the wires according to Figure 2.1.
  • Set all switches (S1-S4) in position 2-3.
  • Adjust the sensitivity of the microphone on the MADR board.

It is possible to place the MADR board on one of the mounting rails in the connection field of the exchange. Then you must run a screened cable from the microphone to the MADR board and run the GND wire to exchange GND on the Subscriber connection board.

Programming

  • No programming in necessary to use this application. We do however recommend that you program the physical connection for the PA system as a substation.

Additional information

If an electret microphone is used, the MADR board has to be modified.

Related articles