(198 intermediate revisions by 3 users not shown) |
Line 1: |
Line 1: |
− | [[File:Turbine config 1.PNG|thumb|700px]] | + | The [[:Category:Stations#Turbine_stations|Turbine Intercom stations]] can be set to operate in one out of three different modes: |
− | The Turbine IP stations are configured both through their web interface and in AlphaPro. For station configuration, there are essentially three parameters to set:
| + | * [[IP Station Configuration - ICX-AlphaCom mode|ICX-AlphaCom mode]] |
− | *AlphaCom IP address | + | * [[SIP Intercom - Web Interface|SIP mode]] |
− | *Station directory number | + | * [[Getting Started (IC-Edge)|Edge mode]] |
− | *Station IP address | |
− | ''Advanced configuration options as described in Advanced Configuration Options are not mandatory for the station to function properly''
| |
− | <br/>
| |
| | | |
− | =AlphaCom Configuration=
| + | Choose one of the links above according to what mode you need to configure. |
− | The Turbine Stations are connected to the AlphaCom XE server/exchange which is the heart of the STENTOFON security and communication system. The communication between the AlphaCom XE exchange and the Turbine Stations utilize the STENTOFON CCoIP® protocols. The AlphaCom XE server/exchange includes all main service configurations for the IP stations and only a minimum configuration is needed to be carried out on the actual station.
| |
| | | |
− | ==Logging into the Station==
| |
− | Access the station by logging into the web interface using a standard web browser:
| |
− | :1. Open a web browser
| |
− | :2. In the browser’s address bar, type the station IP address and press the ENTER key
| |
− | ::- The station login page will be displayed.
| |
− | [[File:TCIS Configuration-4.PNG|thumb|left|500px]]
| |
− | <br style="clear:both;" />
| |
− | To log into the station:
| |
− | :1. Click '''Login'''
| |
− | :2. Enter the default User name: '''admin'''
| |
− | :3. Enter the default password: '''alphaadmin'''
| |
− | The '''Station Information''' page will now be displayed, showing the IP station configuration and status.
| |
| | | |
− | '''''Note that the user interface and parameters displayed in the following sections are dependent on the Turbine station type (Compact, Industrial or Ex) selected.'''''
| |
| | | |
− | ==Main Settings for Compact Stations==
| + | [[Category: Turbine Configuration]] |
− | * Click '''Station Main > Main Settings''' to access the page for configuring station mode and IP parameters.
| |
− | [[File:TCIS Configuration-5.PNG|thumb|left|500px]] | |
− | <br style="clear:both;" />
| |
− | | |
− | '''<u>Station Mode</u>'''
| |
− | * Select the '''Use Alphacom''' radio-button
| |
− | | |
− | '''<u>Turbine Frontboard</u>'''
| |
− | Depending on the type of Turbine Compact station, select one of the options from the drop-down box:
| |
− | ::'''- Kit'''
| |
− | ::'''- Normal (TCIS-1, TCIS-2, TCIS-3)'''
| |
− | ::'''- OLED Labels (TCIS-4, TCIS-5)'''
| |
− | ::'''- Scrolling Station (TCIS-6)'''
| |
− | | |
− | '''<u>Registration Settings</u>'''
| |
− | * Enter the IP address of the AlphaCom server/exchange in which the IP station is to be a subscriber in the '''AlphaCom IP-address''' field.
| |
− | * Enter the directory no. of the station in the '''Directory Number''' field.
| |
− | ::- If a directory number is not entered, the station will register with its MAC address. The MAC address is found on the '''Station Information''' page and needs to be entered into AlphaPro.
| |
− | | |
− | '''<u>IP Settings</u>'''
| |
− | * '''DHCP''' – Select this option if the IP station shall receive IP Settings from a DHCP server.
| |
− | * '''Static IP''' – Select this option if the IP station shall use a static IP address. Enter values for:
| |
− | ::- '''IP-address'''
| |
− | ::- '''Subnet-mask'''
| |
− | ::- '''Gateway'''
| |
− | ::- '''DNS Server 1''' (option for network administration)
| |
− | ::- '''DNS Server 2''' (option for network administration)
| |
− | ::- '''Hostname''' (option for network administration)
| |
− | | |
− | '''<u>Read IP Address</u>'''
| |
− | * Check the '''Read IP Address''' box to enable an unregistered station to speak the IP address when the call button is pressed.
| |
− | | |
− | Click '''Save''' followed by '''Apply''' to apply the new configuration settings.
| |
− | | |
− | ==Main Settings for Industrial Stations==
| |
− | * Click '''Station Main > Main Settings''' to access the page for configuring station mode and IP parameters.
| |
− | [[File:Turbine config 2.PNG|thumb|left|500px]]
| |
− | <br style="clear:both;" />
| |
− | | |
− | '''<u>Station Mode</u>'''
| |
− | * Select the '''Use Alphacom''' radio-button
| |
− | | |
− | '''<u>Product Model and Accessory</u>'''
| |
− | Depending on the type of Turbine Extended station, select one of the options from the drop-down boxes:
| |
− | | |
− | '''Model:'''
| |
− | ::'''- Kit'''
| |
− | ::'''- TFIE-1'''
| |
− | ::'''- TFIE-2'''
| |
− | | |
− | '''Accessory:'''
| |
− | ::'''- Turbine Handset'''
| |
− | ::'''- Handheld Microphone'''
| |
− | ::'''- Turbine Headset'''
| |
− | | |
− | '''Audio Level:'''
| |
− | ::'''- Enable full audio output'''
| |
− | | |
− | '''''It is recommended to use an external power supply if full audio output is enabled. If the station is only powered by the PoE switch, full audio output may lead to a reboot of the switch.'''''
| |
− | | |
− | '''<u>Registration Settings</u>'''
| |
− | * '''AlphaCom IP-address:''' Enter the IP address of the AlphaCom server/exchange in which the IP station is to be a subscriber.
| |
− | * '''Secondary AlphaCom IP-address:''' Enter the secondary IP address of the AlphaCom server/exchange in which the IP station is to be a subscriber.
| |
− | * '''Directory Number:''' Enter the directory number of the station.
| |
− | ::- If a directory number is not entered, the station will register with its MAC address. The MAC address is found on the '''Station Information''' page and needs to be entered into AlphaPro.
| |
− | | |
− | '''<u>IP Settings</u>'''
| |
− | * '''DHCP''' – Select this option if the IP station shall receive IP Settings from a DHCP server.
| |
− | * '''Static IP''' – Select this option if the IP station shall use a static IP address. Enter values for:
| |
− | ::- '''IP-address'''
| |
− | ::- '''Subnet-mask'''
| |
− | ::- '''Gateway'''
| |
− | ::- '''DNS Server 1''' (option for network administration)
| |
− | ::- '''DNS Server 2''' (option for network administration)
| |
− | ::- '''Hostname''' (option for network administration)
| |
− | | |
− | '''<u>Read IP Address</u>'''
| |
− | * Check the '''Read IP Address''' box to enable an unregistered station to speak the IP address when the call key, number keys or DAKs are pressed.
| |
− | * Click '''Save''' followed by '''Apply''' to apply the new configuration settings.
| |
− | | |
− | ==Main Settings for Ex Stations==
| |
− | * Click '''Station Main > Main Settings''' to access the page for configuring station mode and IP parameters.
| |
− | [[File:Turbine config 3.PNG|thumb|left|500px]]
| |
− | <br style="clear:both;" />
| |
− | | |
− | '''<u>Station Mode</u>'''
| |
− | * Select the '''Use Alphacom''' radio-button
| |
− | | |
− | '''<u>Product Model and Accessory</u>'''
| |
− | Depending on the type of Turbine Extended station, select one of the options from the drop-down boxes:
| |
− | | |
− | '''Model:'''
| |
− | ::'''- TFIX-1'''
| |
− | ::'''- TFIX-2'''
| |
− | ::'''- TFIX-3'''
| |
− | | |
− | '''Accessory:'''
| |
− | ::'''- Turbine Handset'''
| |
− | ::'''- Handheld Microphone'''
| |
− | ::'''- Turbine Headset'''
| |
− | | |
− | '''<u>Registration Settings</u>'''
| |
− | * '''AlphaCom IP-address:''' Enter the IP address of the AlphaCom server/exchange in which the IP station is to be a subscriber.
| |
− | * '''Secondary AlphaCom IP-address:''' Enter the secondary IP address of the AlphaCom server/exchange in which the IP station is to be a subscriber.
| |
− | * '''Directory Number:''' Enter the directory number of the station.
| |
− | ::- If a directory number is not entered, the station will register with its MAC address. The MAC address is found on the '''Station Information''' page and needs to be entered into AlphaPro.
| |
− | | |
− | '''<u>IP Settings</u>'''
| |
− | * '''DHCP''' – Select this option if the IP station shall receive IP Settings from a DHCP server.
| |
− | * '''Static IP''' – Select this option if the IP station shall use a static IP address. Enter values for:
| |
− | ::- '''IP-address'''
| |
− | ::- '''Subnet-mask'''
| |
− | ::- '''Gateway'''
| |
− | ::- '''DNS Server 1''' (option for network administration)
| |
− | ::- '''DNS Server 2''' (option for network administration)
| |
− | ::- '''Hostname''' (option for network administration)
| |
− | | |
− | '''<u>Read IP Address</u>'''
| |
− | * Check the '''Read IP Address''' box to enable an unregistered station to speak the IP address when the call key, number keys or DAKs are pressed.
| |
− | * Click '''Save''' followed by '''Apply''' to apply the new configuration settings.
| |
− | | |
− | ==Advanced AlphaCom Settings==
| |
− | * Select '''Advanced AlphaCom''' to access the page for configuring parameters for audio, I/O settings, OLED labels, address book, sound detection.
| |
− | | |
− | ==Audio Settings==
| |
− | To configure audio settings:
| |
− | * Select '''Advanced Alphacom -> Audio''' from the menu
| |
− | [[File:Turbine config 4.PNG|thumb|left|500px]]
| |
− | <br style="clear:both;" />
| |
− | | |
− | * Select or set values for the parameters:
| |
− | ::- Microphone Sensitivity
| |
− | ::- Automatic Volume Control
| |
− | ::- Debug Automatic Volume Control
| |
− | ::- Conversation Mode
| |
− | ::- Audio profile
| |
− | ::- Line Out Source
| |
− | | |
− | '''<u>Microphone Sensitivity</u>'''
| |
− | ::- Select the sensitivity level in the range 0 to 7 from the drop-down box. The default setting is 5.
| |
− | ''If used as a local PA panel, a setting in the 1 to 3 range will reduce the chance of acoustic feedback (howling).''
| |
− | | |
− | '''<u>Volume Control Ch1 & Ch2</u>'''
| |
− | ::- Offset Gain (default routed to Amplifier/Speaker)
| |
− | ::- Valid range: -62 to +24 dB
| |
− | '''''This feature must be used with caution as incorrect settings may severely degrade the performance of the echo-cancelling algorithm.'''''
| |
− | | |
− | '''<u>Automatic Volume Control</u>'''
| |
− | ::- Check the box to enable automatic volume control that is adjusted according to the noise level
| |
− | | |
− | '''<u>Debug Automatic Volume Control</u>'''
| |
− | ::- Check the box to show current volume level on OLED display
| |
− | | |
− | '''<u>Conversation Mode</u>'''
| |
− | For this parameter, there are five options:
| |
− | ::'''- Full Open Duplex''': normal mode with echo cancellation
| |
− | ::'''- Robust Duplex''': Option used when open duplex fails due to excessive speaker loudness, microphone overload or very high nonlinear distortions.
| |
− | ::'''- Half Duplex Switching''': switches speech direction depending on who speaks the loudest
| |
− | ::'''- Push-To-Talk''': f-duplex communication. Initially the microphone is shut off. Push the M-button to open the microphone, and release to listen. (Only applicable to stations with M-key)
| |
− | ::'''- Open''': Full Open Duplex without echo cancellation
| |
− | | |
− | '''<u>Line Out Source</u>'''
| |
− | This parameter can play audio either from VoIP signal ('''Speaker''') or directly from '''Microphone'''.
| |
− | | |
− | The parameter sets the source for the '''Line Out''' signal accessible on the I/O terminal bank. The '''Line Out''' signal can either be the incoming signal ('''Speaker''') or the signal picked up by the Microphone ('''Microphone''').
| |
− | | |
− | When used with an external amplifier (and speakers), use '''Speaker'''. When using the built-in microphone as an input to another system, use '''Microphone'''.
| |
− | | |
− | '''<u>Audio Profile</u>'''
| |
− | This parameter has the following options:
| |
− | ::- Normal
| |
− | ::- Noisy Environment
| |
− | ::- Very Noisy Environment
| |
− | ::- Advanced
| |
− | * See also [[Turbine Audio Profiles]]
| |
− | | |
− | * Select '''Advanced''' to access additional and detailed menu options for audio settings such as noise and echo cancellation:
| |
− | [[File:TCIS Configuration-7.PNG|thumb|left|500px]]
| |
− | <br style="clear:both;" />
| |
− | '''Note!''' These parameters are optional.
| |
− | | |
− | The functions and default values for each parameter are described under '''Advanced Audio Settings'''.
| |
− | | |
− | ==I/O Settings==
| |
− | * Select '''Advanced AlphaCom > I/O Settings''' from the menu
| |
− | [[File:TCIS Configuration-8.PNG|thumb|left|500px]]
| |
− | <br style="clear:both;" />
| |
− | | |
− | * Select either '''Input''' or '''Output''' options from the drop-down box for '''I/O Pins''' 1 to 6.
| |
− | | |
− | ==OLED Labels==
| |
− | '''NOTE!''' Only Turbine stations configured with OLED Labels (TCIS-4, TCIS-5) under Main Settings will have this menu option.
| |
− | * Select Advanced AlphaCom> OLED Labels from the menu
| |
− | [[File:TCIS Configuration-9.PNG|thumb|left|500px]]
| |
− | <br style="clear:both;" />
| |
− | | |
− | '''<u>OLED Display Text</u>'''
| |
− | * Enter display text in the relevant fields for OLED 1 and OLED 2.
| |
− | | |
− | '''<u>OLED Font Size</u>'''
| |
− | * The font size can be either '''12''' or '''16'''
| |
− | | |
− | '''<u>OLED Brightness</u>'''
| |
− | * Brightness: '''Default, Bright, Extra Bright'''
| |
− | | |
− | ==Keyboard Settings==
| |
− | '''Note!''' This menu option is only available for TFIE/TFIX stations.
| |
− | * Select Advanced AlphaCom -> Keyboard Settings from the menu
| |
− | [[File:TFIE Keyboard.PNG|thumb|left|500px]]
| |
− | <br style="clear:both;" />
| |
− | The keyboard layout was changed and by inspecting the PCB number it will reveal the type of keyboard to use.
| |
− | * PCB 8127_2 = Keyboard Type 0: Turbine Extended Keyboard Matrix
| |
− | * PCB 8127_1 = Keyboard Type 1: Turbine Extended Old Keyboard Matrix
| |
− | The PCB number can be found by opening the front and looking at the top of the keyboard PCB.
| |
− | [[File:IMAG0371.jpg|thumb|left|500px]]
| |
− | <br style="clear:both;" />
| |
− | | |
− | ==Address Book==
| |
− | '''NOTE!''' Only the Turbine station configured as a '''Scrolling Station (TCIS-6)''' under '''Main Settings''' will have this menu option.
| |
− | * Select '''Advanced AlphaCom -> Address Book''' from the menu
| |
− | [[File:TCIS Configuration-10.PNG|thumb|left|500px]]
| |
− | <br style="clear:both;" />
| |
− | | |
− | '''<u>Default Display Text</u>'''
| |
− | * The idle text shown in the display may be changed. The default text is: '''Scroll to Select'''
| |
− | | |
− | '''<u>Font Size</u>'''
| |
− | * The font size can be either '''12''' or '''16'''
| |
− | | |
− | '''<u>OLED Brightness</u>'''
| |
− | * Brightness: '''Default, Bright, Extra Bright'''
| |
− | | |
− | '''<u>Start Scrolling After</u>'''
| |
− | * Set the time in minutes after which scrolling should start
| |
− | | |
− | '''<u>Upload Address Book</u>'''
| |
− | [[File:TCIS Configuration-11.PNG|thumb|left|500px]]
| |
− | <br style="clear:both;" />
| |
− | A CSV file consisting of directory numbers and display text with the semi-colon character (;) as delimiter may be uploaded.
| |
− | * Click '''Browse''' to upload a CSV file
| |
− | '''NOTE!''' The CSV file can be 5 kB at maximum. Each character is one byte and every line has 2 invisible control characters (CR and LF) at the end.
| |
− | 1234;Pettersen <== This means 16 byte at CSV file.
| |
− | "1234" are 4 bytes, ";" is one byte, "Pettersen" are 9 bytes and control characters (CR and LF) are 2 bytes
| |
− | | |
− | ==Sound Detection==
| |
− | * Select '''Advanced Alphacom -> Sound Detection''' from the menu
| |
− | [[File:TCIS Configuration-12.PNG|thumb|left|500px]]
| |
− | <br style="clear:both;" />
| |
− | | |
− | '''<u>Sound Detection Settings</u>'''
| |
− | Here you can set the minimum amplitude and duration of the audio, the DAK to activate, etc.
| |
− | | |
− | ==Time Settings==
| |
− | * Select '''Advanced AlphaCom > Time Settings''' from the menu
| |
− | [[File:Turbine config 5.PNG|thumb|left|500px]]
| |
− | <br style="clear:both;" />
| |
− | | |
− | '''<u>Time Settings</u>'''
| |
− | You can enable Network Time Protocol, select the time zone and set the hostname.
| |
− | | |
− | =SIP Configuration=
| |
− | See StentoWiki: http://wiki.stentofon.com/index.php/Main_Page
| |
− | | |
− | =Pulse Configuration=
| |
− | See StentoWiki: http://wiki.stentofon.com/index.php/Main_Page
| |