This article describes how to upgrade the software in the [[:Category:Stations#INCA_stations|INCA family of IP Stations]] via the '''web interface''' of the station. This process is best used for upgrading only a few stations.  
This article describes how to upgrade the software in the [[:Category:INCA Stations|INCA family of IP Stations]]. Note that there is a separate Upgrade procedure for [[Turbine_Software_Upgrade|Turbine stations]].<br>
 
 
 
There are two recommended ways of upgrading the software on the IP Station:
 
* The [[IMT|Intercom management Tool - IMT]]
 
* The [[IP-StationWeb#Manual_Upgrade|web interface of the station]]
 
 
 
It is also possible to upgrade using the web interface ([[AlphaWeb]]) of the AlphaCom XE Audio Server
 
 
 
==Upgrade using the VS-IMT tool ==
 
 
 
Procedure: <br>
 
* Download and install the [[Downloads#VS-IMT_-_Intercom_management_Tool|VS-IMT tool]]
 
* Download the software package [[Downloads#IP_Stations_and_IP-ARIO|A100G80200.02_05_3_4.zip]]. Don't unzip the file.
 
* Start the VS-IMT tool
 
* Select '''Create project''' or open an existing project, and start the wizard that takes you through the discovery and upgrade process, by selecting '''File''' > '''Launch Station Wizard'''
 
* Press '''Next''' to go to Station Discovery. Enter the range of IP addresses (From - To) to search for, and press '''Search'''
 
* When the discovery process is finished, select all stations in the list by checking the '''Select All''' flag
 
 
 
[[File:IMT SelectAll.PNG|thumb|left|500px|Station Discovery window]]
 
<br style="clear:both;" />
 
* Press '''Next''' two times. You've now come to the "Upgrade Stations" window:
 
 
 
[[File:IMT UpgradeWin.PNG|thumb|left|500px|The Upgrade Stations window]]
 
<br style="clear:both;" />
 
 
 
* Import the software package into the VS-IMT tool, and start the upgrade:
 
** Select '''Import image...''', and browse to the '''A100G80200.02_05_3_4.zip''' file, and select '''Open'''
 
** Select the "INCA Image" = '''A100G80200.02_05_3_4'''
 
** In the list box, select the stations to upgrade. Use '''Ctrl + click''' to select multiple stations.
 
 
 
[[File:IMT INCA upgrade 2530.PNG|thumb|left|500px|INCA image and stations selected, ready to start the upgrade]]
 
<br style="clear:both;" />
 
 
 
:* Press the '''Upgrade''' button to start the upgrade process. The status is shown on the screen. The Status will become '''''Success''''' when the station is up and running after the upgrade.
 
  
 +
{{note|
 +
* ''Software upgrade can be done by using the VS-IMT tool, see the article [[IMT - Discover & Upgrade]]. The VS-IMT tool allows mass upgrade of stations.''
 +
* ''There is a separate Upgrade procedure for [[Turbine_Software_Upgrade|Turbine stations]].''
 +
* ''If the station is in SIP mode, [[Automatic Software Upgrade|Automatic Updates]] can also be defined.''  }}
 +
<div style="text-align:left;"> <youtube width="300" height="180">mR-ZnCjA9ag</youtube>  </div>
 +
<br><br>
 
== Upgrade via the web interface of the station ==
 
== Upgrade via the web interface of the station ==
  
[[Image:IP station upgrade one.png|left|400px|thumb|Upgrade of a single IP station]]
+
[[Image:IP station upgrade one.png|left|500px|thumb|Upgrade of a single IP station]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
 
To upgrade the software from the web page of the IP Station:
 
To upgrade the software from the web page of the IP Station:
* Download the software package [[Downloads#IP_Stations_and_IP-ARIO|A100G80200.02_05_3_4.zip]], unzip the file and store the files on a folder on your PC
+
* Download the software package [[Downloads#Stations_and_Devices|A100G80200.02_11_3_1.zip]], unzip the file and store the files on a folder on your PC
 
*Start the [[INCA_Station_Software_upgrade#Installing_a_TFTP_server_on_your_PC|TFTP server]] and browse to the folder were the software files are located
 
*Start the [[INCA_Station_Software_upgrade#Installing_a_TFTP_server_on_your_PC|TFTP server]] and browse to the folder were the software files are located
*Log on to the [[IP-StationWeb|IP Station Web Server]]
+
*[[Logging into an IP Station|Log on to the IP Station Web Server]]
 
*Select '''Station Administration''' > '''Manual upgrade'''
 
*Select '''Station Administration''' > '''Manual upgrade'''
 
*Enter the IP address of the '''TFTP server''' (normally your PC)
 
*Enter the IP address of the '''TFTP server''' (normally your PC)
 
*Enter the name of the software '''Image file''' (include ''bin'' file extension)
 
*Enter the name of the software '''Image file''' (include ''bin'' file extension)
*Enter the '''CRC''' checksum (found in the text file from the downloaded software package)
+
*Enter the '''CRC''' checksum (found in the "A100G80200.02_11_3_1.txt" text file from the downloaded software package)
 
*Click '''Save settings''' to store this information.  
 
*Click '''Save settings''' to store this information.  
  
[[File:INCA upgrade 2534.PNG|left|400px|thumb|Upgrade IP station software]]
+
[[File:INCA Upgrade 21131.PNG|left|500px|thumb|Upgrade of INCA IP station software]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
Line 56: Line 28:
 
*Click on the '''Upgrade''' button to upgrade the software of the IP Station. The procedure takes about 3 minutes.
 
*Click on the '''Upgrade''' button to upgrade the software of the IP Station. The procedure takes about 3 minutes.
 
*The transfer process can be monitored by selecting the '''Log viewer''' tab in the TFTP server program.
 
*The transfer process can be monitored by selecting the '''Log viewer''' tab in the TFTP server program.
 
== Upgrade via the web interface of the AlphaCom server==
 
'''Note:''' This option is only available when the station is used in '''AlphaCom mode'''.
 
[[Image:IP station upgrade many.png|thumb|left|400px|Upgrade multiple stations in one operation]]
 
<br style="clear:both;" />
 
 
Start the TFTP server and browse to the folder were the software file is located.
 
<br/>
 
Log on to the AlphaCom XE Web Server [[AlphaWeb]]:
 
*Select '''System Upgrade''' -> '''IP Stations Upgrade'''
 
*Enter the IP address of the '''TFTP server''', the filename of the software '''Image file''' and its '''CRC''' checksum. Click '''Save'''.
 
*Select which IP Stations to upgrade (or all) and click '''Update Station List'''.
 
*Click '''Start Upgrade Process'''.
 
 
[[Image:IP station information list.jpg|left|400px|thumb|IP station information list]]
 
<br style="clear:both;" />
 
 
The AlphaCom XE will tell each IP Station to contact the TFTP server, download the software image file and carry out the upgrade.
 
<br/>
 
A short status description of the process will be displayed in the Upgrade status column. The message ''IPST:ERROR'' indicates that there is no connection to the TFTP server, or that the ''tftp_test.txt'' file is missing from the folder. The transfer process can be monitored by selecting the '''Log viewer''' tab in the TFTP server program.
 
<br/>
 
 
== Automatic Software Upgrade==
 
'''Note:''' Automatic Software Upgrade is only available when the station is used in '''SIP mode'''.
 
 
A SIP station may be set up to automatically poll software upgrade configuration from a TFTP server. The IP address of this TFTP server can be obtained using DHCP procedures or be manually configured.
 
 
A configuration file should first be created. The relevant parameters in the configuration file are described in Section 7: Configuration File Parameters.
 
 
An example of the parameters for software upgrade in the configuration
 
file is as follows:
 
auto_update_interval=10
 
auto_update_image_type=A100G80200.01_10_1_2.bin
 
auto_update_image_crc=C1466499
 
 
To carry out automatic software upgrade from the station web server:
 
# Start the TFTP server program and set the server path by browsing to the directory where the software file is located.
 
# Log on to the SIP Station web server.
 
# Select '''Advanced Configuration''' > '''Updates'''
 
# Under '''Configuration Updates''' select the radio button for '''Automatic'''. (Automatic Configuration Updates has to be enabled)
 
# Either select the radio button for '''From DHCP''' or enter the IP address of the '''TFTP server'''
 
# Under '''Software Updates''' select the radio button for '''Automatic'''
 
# Either select the radio button for '''From DHCP''' or enter the IP address of the '''TFTP server'''
 
# Under '''Automatic Update Interval''' enter the interval in minutes for checking updates. The value must be between 1 and 999 and the default setting is 60.
 
# Click '''Save configuration for “Updates”'''
 
[[File:INCA-SIP AutoUpdate.png|left|400px|thumb|Software Update page]]
 
<br style="clear:both;" />
 
 
The station will now contact the TFTP server, download the software image and carry out the upgrade.
 
 
* ''Note 1: During an upgrade, the station switch will not be VLAN aware. Make sure the IP station can reach the TFTP server from the native VLAN.''
 
* ''Note 2:  During an upgrade of the station, 802.1X will not be running. Thus if 802.1X reauthentication is enabled and is performed during the upgrade, the station may lose contact with the TFTP server (depending on the configuration when 802.1X authentication fails). If the station loses contact with the TFTP server, it will not be upgraded.''
 
  
 
== Additional Information ==
 
== Additional Information ==
=== AMC-IP Software requirement ===
 
 
There are different minimum software requirements on the AMC-IP board, depending on what IP Station types are being used in the installation:
 
* '''IP Substations''' require minimum AMC-IP software 10.20
 
* '''IP master Stations''' require minimum AMC-IP software 10.50
 
* '''IP DualDisplay Station''' requires minimum AMC-IP software 11.2.3.1
 
* '''IPARIO''' requires minimum AMC-IP software 11.2.3.1
 
* '''Turbine Compact stations''' require AMC software 11.2.3.7
 
<br>
 
 
 
=== Downloading and unzipping the software===
 
=== Downloading and unzipping the software===
Download the IP Station software file from the [[Downloads#Stations|download page]]
+
Download the IP Station software file from the [[Downloads#Stations_and_Devices|download page]]
  
 
Unzip the files to a folder on your PC, e.g. C:\software\IP station\<br>
 
Unzip the files to a folder on your PC, e.g. C:\software\IP station\<br>
 
The zip file contains three files, one ''bin'' file and two ''txt'' files. Example files:
 
The zip file contains three files, one ''bin'' file and two ''txt'' files. Example files:
* ''A100G80200.02_05_3_4.bin'': The actual software image file
+
* '''A100G80200.02_11_3_1.bin''': The actual software image file
* ''A100G80200.02_05_3_4.txt'': You must open this file and make a note of (or copy to the clipboard) the CRC-checksum
+
* '''A100G80200.02_11_3_1.txt''': You must open this file and make a note of (or copy to the clipboard) the CRC-checksum
* ''tftp_test.txt'': Used by the upgrade process to check the communication between the IP Station and the TFTP server
+
* '''tftp_test.txt''': Used by the upgrade process to check the communication between the IP Station and the TFTP server
 
<br>
 
<br>
  
 
===About the file name of the software package===
 
===About the file name of the software package===
*Windows Explorer might be set to hide known file extensions, so the file might appear as ''A100G80200.02_05_3_4'' in Windows Explorer, although the full file name is ''A100G80200.02_05_3_4'''.bin'''''
+
*Windows Explorer might be set to hide known file extensions, so the file might appear as ''A100G80200.02_11_3_1'' in Windows Explorer, although the full file name is ''A100G80200.02_11_3_1'''.bin'''''
 
*The name of the software image file has to be entered with the extension ''.bin''.   
 
*The name of the software image file has to be entered with the extension ''.bin''.   
 
<br>
 
<br>
Line 140: Line 50:
  
 
=== Upgrade in 802.1x environment ===
 
=== Upgrade in 802.1x environment ===
During an upgrade of the IP station, 802.1X will not be running. Thus if 802.1X
+
See [[IEEE_802.1X]]
reauthentication is enabled and is performed during the upgrade, the IP station
 
will lose contact with the TFTP server (depending on the configuration when
 
802.1X authentication fails). If the IP station loses contact with the TFTP server,
 
it will not be upgraded.
 
 
 
  
 
=== Installing a TFTP server on your PC ===
 
=== Installing a TFTP server on your PC ===
Line 166: Line 71:
 
*For Windows10: [http://www.sysprobs.com/enable-ping-reply-and-ftp-traffic-in-windows-10-and-server http://www.sysprobs.com/enable-ping-reply-and-ftp-traffic-in-windows-10-and-server]
 
*For Windows10: [http://www.sysprobs.com/enable-ping-reply-and-ftp-traffic-in-windows-10-and-server http://www.sysprobs.com/enable-ping-reply-and-ftp-traffic-in-windows-10-and-server]
  
 +
If the upgrade is not successful when using the default static IP, it may be due to a network setting.
 +
* Please check the station's subnet mask. If it is 255.255.0.0, change it to 255.255.255.0 and try again
  
 
[[Category:INCA - Restore Factory Defaults and Software Upgrade]]
 
[[Category:INCA - Restore Factory Defaults and Software Upgrade]]

Latest revision as of 14:19, 31 July 2024

This article describes how to upgrade the software in the INCA family of IP Stations via the web interface of the station. This process is best used for upgrading only a few stations.

Note icon




Upgrade via the web interface of the station

Upgrade of a single IP station


To upgrade the software from the web page of the IP Station:

  • Download the software package A100G80200.02_11_3_1.zip, unzip the file and store the files on a folder on your PC
  • Start the TFTP server and browse to the folder were the software files are located
  • Log on to the IP Station Web Server
  • Select Station Administration > Manual upgrade
  • Enter the IP address of the TFTP server (normally your PC)
  • Enter the name of the software Image file (include bin file extension)
  • Enter the CRC checksum (found in the "A100G80200.02_11_3_1.txt" text file from the downloaded software package)
  • Click Save settings to store this information.
Upgrade of INCA IP station software


The station will now try to contact the TFTP server. If the connection cannot be established or the file tftp_test.txt is missing from the folder, the message TFTP_CONN_ERROR is displayed. If the response is TFTP_CONN_OK the settings are saved, and the Upgrade button will appear.

  • Click on the Upgrade button to upgrade the software of the IP Station. The procedure takes about 3 minutes.
  • The transfer process can be monitored by selecting the Log viewer tab in the TFTP server program.

Additional Information

Downloading and unzipping the software

Download the IP Station software file from the download page

Unzip the files to a folder on your PC, e.g. C:\software\IP station\
The zip file contains three files, one bin file and two txt files. Example files:

  • A100G80200.02_11_3_1.bin: The actual software image file
  • A100G80200.02_11_3_1.txt: You must open this file and make a note of (or copy to the clipboard) the CRC-checksum
  • tftp_test.txt: Used by the upgrade process to check the communication between the IP Station and the TFTP server


About the file name of the software package

  • Windows Explorer might be set to hide known file extensions, so the file might appear as A100G80200.02_11_3_1 in Windows Explorer, although the full file name is A100G80200.02_11_3_1.bin
  • The name of the software image file has to be entered with the extension .bin.


Upgrade in VLAN environment

During an upgrade, the IP station switch will not be VLAN aware. Make sure the IP station can reach the TFTP server from the native VLAN.

Upgrade in 802.1x environment

See IEEE_802.1X

Installing a TFTP server on your PC

Settings for tftpd32. "Software" is set as base directory
  • Download the TFTP Server program tftpd32 standard edition (installer) from http://tftpd32.jounin.net/tftpd32_download.html.
  • For 64 bit computers download tftpd64 standard edition (installer)
  • Unzip the tftpdxx.yyy.zip file. (e.g. to C: \tftpdxx\)
  • Run the tftpdxx.exe file. The program is run by selecting the extracted .exe file, no installation is needed.
  • Select the base directory (e.g. C:\Software) by selecting the Settings button, then Browse
  • Turn off every thing except "TFTP Server" under Global Settings. Escpecially important to turn off "DHCP Server", as this server part of the tftpxx application may interfere with other DHCP servers in the network
  • The TFTP Server program must be running during the software upgrade process

Troubleshooting

In the case the upgrade is not successful it may be due to a windows setting.

If the upgrade is not successful when using the default static IP, it may be due to a network setting.

  • Please check the station's subnet mask. If it is 255.255.0.0, change it to 255.255.255.0 and try again