This article is applicable for [[IP Heavy Duty Station V2|IP Heavy Duty Stations (Version 2)]] used in '''ICX-AlphaCom''' mode.
 
This article is applicable for [[IP Heavy Duty Station V2|IP Heavy Duty Stations (Version 2)]] used in '''ICX-AlphaCom''' mode.
  
== AlphaPro Configuration ==
+
==AlphaPro Configuration==
  
=== Hotline Call ===
+
===Hotline Call===
Enable the hotline function by selecting the hotline station in the listbox in '''Users & Stations''', select the '''Station Type''' tab, and check the '''Hotline''' flagg:
+
Enable the hotline function by selecting the hotline station in the listbox in '''Users & Stations''', select the '''Station Type''' tab, and check the '''Hotline''' flag:
  
 
[[File:Hotline Enable.PNG|thumb|left|500px|Enable the Hotline Call flag]]
 
[[File:Hotline Enable.PNG|thumb|left|500px|Enable the Hotline Call flag]]
Line 21: Line 21:
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
=== Hotline Call Delay ===
+
===Hotline Call Delay===
 
By default there is a 5.0 second delay from the handset is lifted until the call is placed. Often you want the call to be placed immediately. To change the delay time, select '''Exchange & System''', '''System''', '''Calls and Options'''.
 
By default there is a 5.0 second delay from the handset is lifted until the call is placed. Often you want the call to be placed immediately. To change the delay time, select '''Exchange & System''', '''System''', '''Calls and Options'''.
 
[[File:HotlineCallDelay.PNG|thumb|left|500px|Default hotline delay is 5.0 sec. Change from 50 to 0 for immediate call]]
 
[[File:HotlineCallDelay.PNG|thumb|left|500px|Default hotline delay is 5.0 sec. Change from 50 to 0 for immediate call]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
=== Direct Access Keys D1 to D3 ===
+
===Direct Access Keys D1 to D3===
 
The Full Keypad models have three Direct Access Keys, D1 to D3, which will trigger DAK key 1, 5 & 7 in the ICX-AlphaCom.  
 
The Full Keypad models have three Direct Access Keys, D1 to D3, which will trigger DAK key 1, 5 & 7 in the ICX-AlphaCom.  
 
[[File:IPHeavuDutyV2DAK.png|thumb|500px|left|Configuring button D1, D2 and D3 in AlphaPro, Users & Stations > DAK window]]
 
[[File:IPHeavuDutyV2DAK.png|thumb|500px|left|Configuring button D1, D2 and D3 in AlphaPro, Users & Stations > DAK window]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
== Additional Call Indication (optional) ==
+
===Ringing in External Loudspeaker===
 +
IP heavy duty is normally used for outgoing calls, and there is no inbuilt speaker to indicate incoming calls.
 +
It is possible to connect an external loudspeaker to hear that the station is called.
 +
This speaker can be minimum 8ohm and is connected to the 10W loudspeaker output (P6-1 and P6-2).
 +
No additional setting is needed for this, and volume is changed in AlphaPro.
 +
[[File:IP_Heavy_Duty_External_Speaker.png|thumb|200px|left|Ringing in External Loudspeaker]]
 +
<br style="clear:both;" />
 +
 
 +
==Additional Call Indication (optional)==
 
The built-in relay in the IP Heavy Duty telephone can be used to operate an additional call indication device, such as a rotary light.
 
The built-in relay in the IP Heavy Duty telephone can be used to operate an additional call indication device, such as a rotary light.
 
[[File:IRR3 IP Heavy Duty.PNG|thumb|400px|left|Additional Call Indication by rotary light]]
 
[[File:IRR3 IP Heavy Duty.PNG|thumb|400px|left|Additional Call Indication by rotary light]]
Line 37: Line 45:
  
 
Additional equipment required:
 
Additional equipment required:
* Rotary light 24VDC (Item 300 6102 041)
+
 
* [[IRR-3 Relay unit|IRR-3 relay box]] (Item 102 0600 992)
+
*Rotary light 24VDC (Item 300 6102 041)
* 24VDC power supply (Minimum 3A)
+
*[[IRR-3 Relay unit|IRR-3 relay box]] (Item 102 0600 992)
 +
*24VDC power supply (Minimum 3A)
  
 
Connection diagram:
 
Connection diagram:
Line 62: Line 71:
  
  
==Related information ==
+
==Related information==
Configuration guide for the previous (version 1) [[IP Heavy Duty Station|IP Heavy Duty Stations]]
+
[[Configuration_guide_for_IP_Heavy_Duty|Configuration guide for the previous (version 1) IP Heavy Duty Stations]]
  
 
[[Category: Turbine Configuration]]
 
[[Category: Turbine Configuration]]

Latest revision as of 08:30, 20 September 2023

AI.png
IP Heavy Duty

This article is applicable for IP Heavy Duty Stations (Version 2) used in ICX-AlphaCom mode.

AlphaPro Configuration

Hotline Call

Enable the hotline function by selecting the hotline station in the listbox in Users & Stations, select the Station Type tab, and check the Hotline flag:

Enable the Hotline Call flag



In Users & Stations, select the DAK button, and enter the call destination on DAK 7:

Call station 321 when lifting the handset


If the hotline call should generate a call to a Ringing Group instead, enter "I 6701" on DAK 7. If the call should be cleared when replacing the handset, enter "C" on DAK 8, else leave DAK 8 blank.

Send Call Request to station 101 when lifting the handset, delete the Call request when replacing the handset


Hotline Call Delay

By default there is a 5.0 second delay from the handset is lifted until the call is placed. Often you want the call to be placed immediately. To change the delay time, select Exchange & System, System, Calls and Options.

Default hotline delay is 5.0 sec. Change from 50 to 0 for immediate call


Direct Access Keys D1 to D3

The Full Keypad models have three Direct Access Keys, D1 to D3, which will trigger DAK key 1, 5 & 7 in the ICX-AlphaCom.

Configuring button D1, D2 and D3 in AlphaPro, Users & Stations > DAK window


Ringing in External Loudspeaker

IP heavy duty is normally used for outgoing calls, and there is no inbuilt speaker to indicate incoming calls. It is possible to connect an external loudspeaker to hear that the station is called. This speaker can be minimum 8ohm and is connected to the 10W loudspeaker output (P6-1 and P6-2). No additional setting is needed for this, and volume is changed in AlphaPro.

Ringing in External Loudspeaker


Additional Call Indication (optional)

The built-in relay in the IP Heavy Duty telephone can be used to operate an additional call indication device, such as a rotary light.

Additional Call Indication by rotary light


Additional equipment required:

  • Rotary light 24VDC (Item 300 6102 041)
  • IRR-3 relay box (Item 102 0600 992)
  • 24VDC power supply (Minimum 3A)

Connection diagram:

Detailed connection diagram



Configuration

The built-in relays in the IP Heavy Duty telephone is controlled by the RCO command in the event handler.

To map the relays of the IP Station to logical RCO's, select Exchange & System -> RCO. Pick a free RCO, select Change and set the RCO Type = Station, enter the physical number of the IP Station, and set pin number = 7 (8 for the second relay).

The relay of IP Station 144 is mapped to RCO 10.


In Users & Stations, select the IP Heavy Duty telephone from the list box, then press Events, and Insert a new event with the following properties. This will cause the relay to operate during the ringing of an incoming call.

When station 144 receives a call in private ringing mode, RCO 10 will be operated. This will again operate the relay and the rotary light.


Note: The internal ringer device is not in use. The reason is that the housing of the IP telephones are also used in analog versions of the telephone, connected to regular 2-wire telephones lines. Then the ringer is operated by the ringing voltage from the telephone exchange. Although the ringer device is not in use in the IP Heavy Duty station, it has not been removed as it would jeopardize the IP rating of the station.