Actions

Difference between revisions of "%prci"

From Zenitel Wiki

(Examples)
 
(8 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
{{AI}}  
 
{{AI}}  
The '''%prci''' macro is used in the [[Event Handler]] to check state of a physical input on an IP Station or IP-ARIO.
+
The '''%prci''' macro is used in the [[Event Handler]] to check state of a physical input on a Zenitel IP Device.
  
===Syntax===
+
==Syntax==
 
  '''%prci(station,input_no)'''
 
  '''%prci(station,input_no)'''
  
Return 1/0 state of a physical input
+
Return 1 (active) or 0 (not active) state of a physical input
 
* station:  Physical number 1 - 552
 
* station:  Physical number 1 - 552
 
* input_no: Input number 1 - 8
 
* input_no: Input number 1 - 8
  
===Examples===
+
==Examples==
  %prci(5,1)           - ''Return state of input 1 on station 5''
+
  %prci(5,1)   - ''Return state of input 1 on station 5''
 +
 
 +
== Notes ==
 +
One can use the [[Faulty Station Line (Event Type)|Faulty Station Line - OFF]] together with %prci to read the status of the inputs when a device registers to the ICX-AlphaCom. However, one have to insert a small delay ([[SET TIMER|$ST]]) of approx. 5 seconds from the device registers to the inputs are read.
  
  

Latest revision as of 09:30, 18 November 2024

AI.png

The %prci macro is used in the Event Handler to check state of a physical input on a Zenitel IP Device.

Syntax

%prci(station,input_no)

Return 1 (active) or 0 (not active) state of a physical input

  • station: Physical number 1 - 552
  • input_no: Input number 1 - 8

Examples

%prci(5,1)   - Return state of input 1 on station 5

Notes

One can use the Faulty Station Line - OFF together with %prci to read the status of the inputs when a device registers to the ICX-AlphaCom. However, one have to insert a small delay ($ST) of approx. 5 seconds from the device registers to the inputs are read.



Back to Event_Handler#List_of_context_parameters.