Actions

Difference between revisions of "%prci"

From Zenitel Wiki

 
(4 intermediate revisions by the same user not shown)
Line 12: Line 12:
 
  %prci(5,1)  - ''Return state of input 1 on station 5''
 
  %prci(5,1)  - ''Return state of input 1 on station 5''
  
 
+
== Notes ==
 +
One can use the [[Faulty Station Line (Event Type)|Faulty Station Line - OFF]] together with %prci to read the status of the inputs when a device registers to the ICX-AlphaCom. However, one have to insert a small delay ([[SET TIMER|$ST]]) of approx. 5 seconds from the device registers to the inputs are read.
  
  

Latest revision as of 09:30, 18 November 2024

AI.png

The %prci macro is used in the Event Handler to check state of a physical input on a Zenitel IP Device.

Syntax

%prci(station,input_no)

Return 1 (active) or 0 (not active) state of a physical input

  • station: Physical number 1 - 552
  • input_no: Input number 1 - 8

Examples

%prci(5,1)   - Return state of input 1 on station 5

Notes

One can use the Faulty Station Line - OFF together with %prci to read the status of the inputs when a device registers to the ICX-AlphaCom. However, one have to insert a small delay ($ST) of approx. 5 seconds from the device registers to the inputs are read.



Back to Event_Handler#List_of_context_parameters.