Actions

Difference between revisions of "Auto-attendant"

From Zenitel Wiki

(Configuration)
(Configuration)
Line 27: Line 27:
 
Adding a second auto-attendant:
 
Adding a second auto-attendant:
  
In directory & Features, press Insert, and add a new number with the following properties:
+
In '''Directory & Features''', press '''Insert''', and add a new number with the following properties:
  
 
{| border="1"
 
{| border="1"

Revision as of 10:00, 9 September 2010

The auto-attendant feature provides voice guided menus

The Auto-attendant feature provides voice guided menus for handling incoming calls:

  • Play a welcome message on incoming telephone calls
  • Press a digit to re-route the call
  • If no digits are pressed, the call will be automatically re-routed after 10 sec.

Configuration

Directory number 9550 is included by default.

Recording the message

To record a welcome message:

  • From a SuperUser station dial 8180 + 9550. Press and hold the M-key while recording.
  • Example: ”Welcome to Procom Ltd, press 1 for switchboard, press 2 for Sales department, press 3 for Marketing department, or wait for an answer
  • Release M-key to listen to the message. Press M-key again to do a new recording, or
  • Press 8 to save.

Digit routing

Auto-attendant digit routing: Digit 1 calls station 101, digit 2 calls station 123, digit 3 calls station 5432, and digit 0 repeats the voice menu

The Auto-attendant function 9550 is using the DAK table of physical station 500 for the "digit" actions. In the Users & Stations window in AlphaPro, select physical number 500 in the list box, and press the button DAK. In the DAK table enter the destination for digit 1-9, and 0.

Adding more auto-attendant numbers

Up to 3 auto-attendant numbers are supported. Directory numbers for the first auto-attendant is included by default. For the second and third auto-attendant you have to add new directory numbers from AlphaPro.

Adding a second auto-attendant:

In Directory & Features, press Insert, and add a new number with the following properties:

Dirno DisplayText Feature Parmeter 1 (ID) Parmeter 2 Parmeter 3 Description
9551 AutoAttendant2 105 2 1 501 Auto-attendant number 2, using the DAK table of physical number 501


Adding a third auto-attendant:

In directory & Features, press Insert, and two new numbers with the following properties:

Dirno DisplayText Feature Parmeter 1 (ID) Parmeter 2 Parmeter 3 Description
8183 MenuMsg3 111 11 3 0 Auto-attendant number 2
9552 AutoAttendant2 105 3 1 502 Auto-attendant number 3, using the DAK table of physical number 502

Hardware and license requiements

  • Hardware: The auto-attendant feature require AMC-IP hardware version 8000/5 or 8000/6 (Black PCB).
  • License: Auto-attendant requires a Basic (1 auto-attendant) or Enhanced (3 auto-attendants) Audio Messaging license.