Difference between revisions of "Unlock intercom station with password"
From Zenitel Wiki
Line 8: | Line 8: | ||
* Program two new event as described below. | * Program two new event as described below. | ||
− | |||
'''Event 1''' - Unlock the station by moving the station to COS 1 when dialing passcode 9200. A 10,0 second timer is started. | '''Event 1''' - Unlock the station by moving the station to COS 1 when dialing passcode 9200. A 10,0 second timer is started. | ||
{| | {| | ||
Line 29: | Line 28: | ||
The parameter W100 = 10.0 seconds. Change if required. | The parameter W100 = 10.0 seconds. Change if required. | ||
− | + | ||
+ | |||
'''Event 2''' - After timeout, lock the station by moving it to COS 2. | '''Event 2''' - After timeout, lock the station by moving it to COS 2. | ||
{| | {| |
Revision as of 14:42, 2 May 2013
This article describes how a master station can be locked in idle, and unlocked by dialing a passcode (Event Trigger). When the code is dialed, the station will be unlocked for a preset periode of time, then it will automatically be locked.
- In AlphaPro - Directory & Features, Insert a new event trigger directory number with feature number 85, e.g. 9200.
- In AlphaPro - COS, modify COS 2 to include feature 85 only.
- Program two new event as described below.
Event 1 - Unlock the station by moving the station to COS 1 when dialing passcode 9200. A 10,0 second timer is started.
Event Owner: | Stations w/UDP, Id: 8 (All stations) |
Event type: | 15 – Event trigger |
When change to: | ON |
When related to: | Directory number, Id: 9200 |
Action: | $SSC L%1.dir U1 |
$ST L%1.dir W100 L9200 |
The parameter W100 = 10.0 seconds. Change if required.
Event 2 - After timeout, lock the station by moving it to COS 2.
Event Owner: | Stations w/UDP, Id: 8 (All stations) |
Event type: | 21 – Event timer |
When change to: | ON |
When related to: | Directory number, Id: 9200 |
Action: | $SSC L%1.dir U2 |