Actions

Difference between revisions of "TFIX - Installation Solutions"

From Zenitel Wiki

(Single TFIX with beacon)
(Multiple TFIX'es with beacon)
Line 38: Line 38:
 
Multiple TFIX'es with beacon in the EX zone, where all controlling equipment is located in the server room. <br/>
 
Multiple TFIX'es with beacon in the EX zone, where all controlling equipment is located in the server room. <br/>
 
For every sixth TFIX with beacon you need:
 
For every sixth TFIX with beacon you need:
* 1 Turbine compact Kit; [[TKIS-2]]
+
* 1 Turbine compact Kit; [[TKIS-2 VoIP Intercom Module - 1008131020|TKIS-2]]
 
* 1 IP Station License
 
* 1 IP Station License
 
* 1 Multi-relay board; [[MRBD]]
 
* 1 Multi-relay board; [[MRBD]]
Line 44: Line 44:
 
* 1 Flowire unit; FCDC
 
* 1 Flowire unit; FCDC
 
* 1 24VDC PSU for the Flowire
 
* 1 24VDC PSU for the Flowire
* 6 Relay boxes; [[IRR-3]]
+
* 6 Relay boxes; [[IRR-3 Relay unit|IRR-3]]
 
* 6 Beacons; BEX24O or BEX230O
 
* 6 Beacons; BEX24O or BEX230O
 
* 6 Powers supplies; 24VDC or 230VAC
 
* 6 Powers supplies; 24VDC or 230VAC
Line 52: Line 52:
 
[[File:Beacon and IRR-3.png|thumb|left|500px|Detailed connection diagram]]
 
[[File:Beacon and IRR-3.png|thumb|left|500px|Detailed connection diagram]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 +
 +
== Related articles ==
 +
* [[Turbine Compact and MRBD]]
 +
* [[IRR-3 Relay unit]]

Revision as of 11:49, 2 October 2015

ARTICLE UNDER CONSTRUCTION!!!

TFIX station with beacon

A beacon lamp can be used to indicate an incoming call or PA announcement.

Single TFIX with beacon

A single TFIX with beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.
The cabinet consist of:

  • 1 Turbine extended kit; TKIE
  • 1 IP Station License
  • 1 Turbine Relay board; TA-10
  • 1 Power supply; 24VDC or 230VAC
  • 1 Flowire unit; FCDC
  • 1 24VDC PSU for the Flowire
TFIX Beacon Single.png


Detailed connection diagram


Multiple TFIX'es with beacon

Multiple TFIX'es with beacon in the EX zone, where all the controlling equipment is located in the safe zone in closed cabinets in a more convenient placements out in the field.
Each cabinet consist of:

  • 1 Turbine extended kit; TKIE
  • 1 IP Station License
  • 1 Turbine Relay board; TA-10
  • 1 Power supply; 24VDC or 230VAC
  • 1 Flowire unit; FCDC
  • 1 24VDC PSU for the Flowire
TFIX Beacon Multiple2.png



Multiple TFIX'es with beacon in the EX zone, where all controlling equipment is located in the server room.
For every sixth TFIX with beacon you need:

  • 1 Turbine compact Kit; TKIS-2
  • 1 IP Station License
  • 1 Multi-relay board; MRBD
  • 1 24VDC PSU: for the MRBD
  • 1 Flowire unit; FCDC
  • 1 24VDC PSU for the Flowire
  • 6 Relay boxes; IRR-3
  • 6 Beacons; BEX24O or BEX230O
  • 6 Powers supplies; 24VDC or 230VAC
TFIX Beacon Multiple1.png


Detailed connection diagram


Related articles