Difference between revisions of "INCA Station Kit Restore Factory Defaults"
From Zenitel Wiki
(→Restore with Static IP) |
|||
Line 25: | Line 25: | ||
<u>'''Factory default values:'''</u> | <u>'''Factory default values:'''</u> | ||
+ | * Station Mode: '''Pulse''' | ||
* Station IP address: '''169.254.1.100''' | * Station IP address: '''169.254.1.100''' | ||
* AlphaCom IP address: '''169.254.1.5''' | * AlphaCom IP address: '''169.254.1.5''' |
Revision as of 09:39, 25 October 2016
Restore to Factory Default for IP Stations without Display and Key:
- IP Master Station Kit 100809300
- IP Substation Kit - 1008090200
- IP Speaker - 1401002100/1401002500
- IP Heavy Duty - 1008072200
For IP Master Station kits with display, see: INCA Display Station Restore Factory Defaults
The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.
Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
Restore with Static IP
- While pressing the button, power up the station kit.
- When the station kit LED starts blinking, release the button after exactly 2 blinks.
- Let the LED blink for exactly 2 more times, then press the button again.
- Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
- Release the button and the station kit will restart with the factory default settings.
Factory default values:
- Station Mode: Pulse
- Station IP address: 169.254.1.100
- AlphaCom IP address: 169.254.1.5
- Username: admin (Software 01.06 and earlier: ADMIN)
- Password: alphaadmin (Software 01.06 and earlier: alphacom)
Restore with Activated DHCP
The DHCP option is available from software version 01.07.
- While pressing the button, power up the station kit.
- When the station kit LED starts blinking, release the button after exactly 2 blinks.
- Let the LED blink for exactly 4 more times, then press the button again.
- Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
- Release the button and the station kit will restart with the factory default settings.
Factory default values:
- Station IP address: (determined by DHCP server)
- AlphaCom IP address: 169.254.1.5
- Username: admin (Software 01.06 and earlier: ADMIN)
- Password: alphaadmin (Software 01.06 and earlier: alphacom)