Faults in the ENA Amplifier can be reported to a display station, e.g. to [[IP Desktop Master Station - 1008001000|IP Desktop]], [[IP Dual Display Station - 1008007000|DualDisplay]] or [[CRM V - Control Room Master|CRMV station]]. This is achieved by using [[Station Fault (Event Type)|event 43 - Station Fault Report]], which is triggered whenever the ENA amplifier reports a fault. | Faults in the ENA Amplifier can be reported to a display station, e.g. to [[IP Desktop Master Station - 1008001000|IP Desktop]], [[IP Dual Display Station - 1008007000|DualDisplay]] or [[CRM V - Control Room Master|CRMV station]]. This is achieved by using [[Station Fault (Event Type)|event 43 - Station Fault Report]], which is triggered whenever the ENA amplifier reports a fault. |
Revision as of 13:22, 12 April 2018
Faults in the ENA Amplifier can be reported to a display station, e.g. to IP Desktop, DualDisplay or CRMV station. This is achieved by using event 43 - Station Fault Report, which is triggered whenever the ENA amplifier reports a fault.
In order to have one common event for all ENA amplifiers, include the amplifiers in an UDP Group. Here UDP Group 3 is used as an example.
In AlphaPro, select Exchange & System > Events, and Insert a new event with the following properties:
Action Command:
IF %chg(1,0) $STM %1.ref L164 U%op(70,+,%sev) '(%1.dir) %2.nam' STOP ENDIF $CANM %1.ref L164 NM253 U%op(70,+,%sev)
The event string will send a station-mail ($STM) to station 164 for all new fault codes. When a fault is removed the event is reported "OFF", and the mail message is automatically deleted. ($CANM). If you want the mail message to remain in the station also after the fault is gone, simply change "When Change To" = ON (not ON or OFF).
The priority of the mail will be the fault type (subevent) + 70. The mail text will contain the directory number of the amplifier and the default fault text. Customized fault text can be used instead of the default text.