* Pulse (VS-IS 4.x) can be upgraded to IC-EDGE, but the whole system needs to run with the same [[Downloads#Turbine_stations|Turbine software]] (VS-IS 5.0 or newer). | * Pulse (VS-IS 4.x) can be upgraded to IC-EDGE, but the whole system needs to run with the same [[Downloads#Turbine_stations|Turbine software]] (VS-IS 5.0 or newer). | ||
− | * In an IC-EDGE System, [[:Category:Stations#INCA_stations|INCA | + | * In an IC-EDGE System, [[:Category:Stations#INCA_stations|INCA stations]] cannot be used as the Edge Controller. |
* TCIV video intercoms should not be used as the Edge Controller for systems exceeding 4 devices. | * TCIV video intercoms should not be used as the Edge Controller for systems exceeding 4 devices. | ||
* VS-IMT can be used for station discovery and upgrade but must not be used to configure IC-EDGE. | * VS-IMT can be used for station discovery and upgrade but must not be used to configure IC-EDGE. |
Revision as of 10:06, 11 September 2019
This article describes how to upgrade from Pulse (VS-IS 4.x) to IC-EDGE.
Contents
Prerequisite
- Pulse (VS-IS 4.x) can be upgraded to IC-EDGE, but the whole system needs to run with the same Turbine software (VS-IS 5.0 or newer).
- In an IC-EDGE System, INCA stations cannot be used as the Edge Controller.
- TCIV video intercoms should not be used as the Edge Controller for systems exceeding 4 devices.
- VS-IMT can be used for station discovery and upgrade but must not be used to configure IC-EDGE.
Pulse to IC-EDGE Licenses
Pulse licenses will be honored in an IC-EGDE System. This means that when you upgrade firmware from VS-IS 4.x to 5.x your Pulse licenses will work for IC-EDGE.
More information regarding licensing in IC-EDGE can be found here.
Select IC-EDGE Controller
If the Pulse Server is an Inca station you must select a different device (Turbine) as the IC-EDGE Controller.
Maximum number of devices with TCIV as the IC-EDGE Controller is 4.
Upgrade the Stations
In an IC-EDGE system all station must be upgraded to IC-EDGE. You cannot mix IC-EDGE and Pulse devices.
Make sure all Turbine station runs 5.0.3.0 or newer.
Inca stations must run 02.10.3.0 or newer.
Software can be found here.
Upgrade procedure using VS-IMT can be found here.
Manual upgrade procedure can be found here.