− | + | == Highlights == | |
+ | * Made to provide critical communication in any environment | ||
+ | * Supports 552 IP stations and 102 analog intercom stations | ||
+ | * Global networking and integration | ||
+ | * IP, SIP and analog station support | ||
+ | * Extended Software Options | ||
+ | * SIM card based software configuration and disaster recovery | ||
+ | * Fully compatible with any AlphaCom system | ||
+ | * Extended memory supports future expansion and new services | ||
+ | * High Quality Professional PA Broadcasting and Messaging services | ||
+ | * Security voice guidance for public safety and building security | ||
+ | * Auto-attendant functionality (Automatic voice supported switchboard) | ||
+ | * Voice supported call guidance | ||
− | == | + | ==Additional Documentation== |
− | + | For more documentation please see http://www.zenitel.com/product/alphacom-xe20 | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
== Installation == | == Installation == | ||
+ | * Up to 4 units may be mounted in one 19” rack if sufficient ventilation is provided. It is recommended to mount a 24 VDC cooling fan module on top of each exchange unit | ||
[[image:AC E20 Installation.jpg|thumb|500px|left|Mounting AlphaCom XE20]] | [[image:AC E20 Installation.jpg|thumb|500px|left|Mounting AlphaCom XE20]] | ||
− | |||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
== Connections == | == Connections == | ||
− | + | * The two-pair star wired intercom cables are connected to connection boards on the cabinet DIN rail or in a separate distribution field | |
− | The two-pair star wired intercom cables are connected to connection boards on the cabinet DIN rail or in a separate distribution field | + | * Each [[ASLT|subscriber line card]] provides 6 freely programmable Remote Control Outputs ([[RCO]]) |
− | Each subscriber line card provides 6 freely programmable Remote Control Outputs (RCO) | + | * Two RJ-45 Ethernet terminals on the [[Filter card AMC-IP|IP filter board]] are used for IP LAN and WAN communication |
− | Two RJ-45 Ethernet terminals on the IP filter board are used for IP LAN and WAN communication | + | * The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols. Eth0 is also used for programming |
− | The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols. Eth0 is also used for programming | + | * 6 [[Audio Program|program distribution]] sources can be connected to the [[APC - AlphaCom Program & Clock Board|APC board]] via an optional program connection board. Up to 64 extra programs may be added using AGA boards with 16 programs per board |
− | 6 program distribution sources can be connected to the APC board via an optional program connection board. Up to 64 extra programs may be added using AGA boards with 16 programs per board | + | * The [[Filter card APC|optional program connection]] board has input for 6 Remote Control Inputs ([[RCI]]) which can initiate programmed actions |
− | The optional program connection board has input for 6 Remote Control Inputs (RCI) which can initiate programmed actions | + | * The exchange is powered from the mains. |
− | The exchange is powered from the mains. | + | [[File:XE20 Connections.PNG|thumb|left|500px]] |
− | + | <br style="clear:both;" /> | |
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
[[Category:Hardware]] | [[Category:Hardware]] | ||
[[Category:AlphaCom XE Exchanges]] | [[Category:AlphaCom XE Exchanges]] |
Revision as of 08:08, 7 August 2015
Highlights
- Made to provide critical communication in any environment
- Supports 552 IP stations and 102 analog intercom stations
- Global networking and integration
- IP, SIP and analog station support
- Extended Software Options
- SIM card based software configuration and disaster recovery
- Fully compatible with any AlphaCom system
- Extended memory supports future expansion and new services
- High Quality Professional PA Broadcasting and Messaging services
- Security voice guidance for public safety and building security
- Auto-attendant functionality (Automatic voice supported switchboard)
- Voice supported call guidance
Additional Documentation
For more documentation please see http://www.zenitel.com/product/alphacom-xe20
Installation
- Up to 4 units may be mounted in one 19” rack if sufficient ventilation is provided. It is recommended to mount a 24 VDC cooling fan module on top of each exchange unit
Connections
- The two-pair star wired intercom cables are connected to connection boards on the cabinet DIN rail or in a separate distribution field
- Each subscriber line card provides 6 freely programmable Remote Control Outputs (RCO)
- Two RJ-45 Ethernet terminals on the IP filter board are used for IP LAN and WAN communication
- The serial ports with RS232 and RS422/RS485 interfaces are used for connecting to equipment using these protocols. Eth0 is also used for programming
- 6 program distribution sources can be connected to the APC board via an optional program connection board. Up to 64 extra programs may be added using AGA boards with 16 programs per board
- The optional program connection board has input for 6 Remote Control Inputs (RCI) which can initiate programmed actions