Actions

Difference between revisions of "Door Opening using Dummy Number (Event Handler)"

From Zenitel Wiki

(Situation)
(Solution)
Line 3: Line 3:
  
 
==Solution==
 
==Solution==
 +
When the operator gets a signal that there is someone at the door he should dial a 'dummy' number, then press digit 6 to operate a relay output (i.e. a [[RCO]]).
 
In the example below any station can dial 9545 + 6 to trigger [[RCO]] 4 for 2 seconds, and disconnect with success-tone.
 
In the example below any station can dial 9545 + 6 to trigger [[RCO]] 4 for 2 seconds, and disconnect with success-tone.
 
Use the two-step event trigger, [[Event trigg on dialing digits|feature 105]].
 
Use the two-step event trigger, [[Event trigg on dialing digits|feature 105]].
 
  
 
==Programming==
 
==Programming==

Revision as of 12:06, 20 November 2008

Situation

Some gates are not equipped with door stations, but the operator should use the same Door opening procedure to open the door.

Solution

When the operator gets a signal that there is someone at the door he should dial a 'dummy' number, then press digit 6 to operate a relay output (i.e. a RCO). In the example below any station can dial 9545 + 6 to trigger RCO 4 for 2 seconds, and disconnect with success-tone. Use the two-step event trigger, feature 105.

Programming

In AlphaPro, Directory & Features, press "Insert" to create a directory number, feature 105, for each door. Directory number 9545 is included by default.
In AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:


Event Handler configuration
Event Owner: The operator station or a UDP group
Event type: 25 – Event Trigger w/User Parameter
Subevent: 6
When change to: ON
When related to: Directory number, Id: 9545
Action: RCO 4 ON 20
  $DISCON_ST L%1.dir U2




Explanation

Subevent 6: digit 6
When Change to ON: When the digit is pressed (not released)
RCO 6 ON 20: Pulse RCO 6 for 2,0 seconds
$DISCON_ST L%1.dir U2: Disconnect the station with successtone