The cabinet consist of:
 
The cabinet consist of:
 
* 1 Turbine extended kit; TKIE
 
* 1 Turbine extended kit; TKIE
* 1 IP Station License
 
 
* 1 Turbine Relay board; TA-10
 
* 1 Turbine Relay board; TA-10
 
* 1 Beacon PSU; 24VDC or 230VAC
 
* 1 Beacon PSU; 24VDC or 230VAC
Line 25: Line 24:
 
Each cabinet consist of:
 
Each cabinet consist of:
 
* 1 Turbine extended kit; TKIE
 
* 1 Turbine extended kit; TKIE
* 1 IP Station License
 
 
* 1 Turbine Relay board; TA-10
 
* 1 Turbine Relay board; TA-10
 
* 1 Beacon PSU; 24VDC or 230VAC
 
* 1 Beacon PSU; 24VDC or 230VAC
Line 39: Line 37:
 
For every sixth TFIX with beacon you need:
 
For every sixth TFIX with beacon you need:
 
* 1 Turbine compact Kit; [[TKIS-2 VoIP Intercom Module - 1008131020|TKIS-2]]
 
* 1 Turbine compact Kit; [[TKIS-2 VoIP Intercom Module - 1008131020|TKIS-2]]
* 1 IP Station License
 
 
* 1 Multi-relay board; [[MRBD]]
 
* 1 Multi-relay board; [[MRBD]]
 
* 1 24VDC PSU: for the MRBD
 
* 1 24VDC PSU: for the MRBD

Revision as of 18:44, 26 October 2015

ARTICLE UNDER CONSTRUCTION!!!

TFIX station with beacon

In noisy areas a beacon lamp can be used to indicate an incoming call or PA announcement.

Single TFIX with beacon

A single TFIX with beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.
The cabinet consist of:

  • 1 Turbine extended kit; TKIE
  • 1 Turbine Relay board; TA-10
  • 1 Beacon PSU; 24VDC or 230VAC
  • 1 Flowire unit; FCDC2
  • 1 24VDC Flowire PSU
TFIX Beacon Single.png


Detailed connection diagram


Multiple TFIX'es with beacon

Multiple TFIX'es with beacon in the EX zone, where all the controlling equipment is located in the safe zone in closed cabinets in a more convenient placements out in the field.
Each cabinet consist of:

  • 1 Turbine extended kit; TKIE
  • 1 Turbine Relay board; TA-10
  • 1 Beacon PSU; 24VDC or 230VAC
  • 1 Flowire unit; FCDC2
  • 1 24VDC Flowire PSU
TFIX Beacon Multiple2.png



Multiple TFIX'es with beacon in the EX zone, where all controlling equipment is located in the server room.
For every sixth TFIX with beacon you need:

  • 1 Turbine compact Kit; TKIS-2
  • 1 Multi-relay board; MRBD
  • 1 24VDC PSU: for the MRBD
  • 1 Flowire unit; FCDC2
  • 1 24VDC Flowire PSU
  • 6 Relay boxes; IRR-3
  • 6 Beacons; BEX24O or BEX230O
  • 6 Beacon Power supplies; 24VDC or 230VAC
TFIX Beacon Multiple1.png


Detailed connection diagram