TFIX - Installation Solutions: Difference between revisions
From Zenitel Wiki
| Line 5: | Line 5: | ||
In noisy areas a beacon lamp and/or a signal bell/horn can be used to indicate an incoming call or PA announcement. | In noisy areas a beacon lamp and/or a signal bell/horn can be used to indicate an incoming call or PA announcement. | ||
== Single TFIX with | == Single TFIX with external signal device == | ||
A single TFIX with | A single TFIX with external signal device in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field. <br/> | ||
The cabinet consist of: | The cabinet consist of: | ||
* 1 Turbine extended kit; TKIE | * 1 Turbine extended kit; TKIE | ||
Revision as of 13:50, 29 October 2015
ARTICLE UNDER CONSTRUCTION!!!
TFIX station with external signal device
In noisy areas a beacon lamp and/or a signal bell/horn can be used to indicate an incoming call or PA announcement.
Single TFIX with external signal device
A single TFIX with external signal device in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.
The cabinet consist of:
- 1 Turbine extended kit; TKIE
- 1 Turbine Relay board; TA-10
- 1 24VDC or 230VAC PSU for signal device
- 1 Flowire unit; FCDC2
- 1 24VDC Flowire PSU
Multiple TFIX'es with beacon
Multiple TFIX'es with beacon in the EX zone, where all the controlling equipment is located in the safe zone in closed cabinets in a more convenient placements out in the field.
Each cabinet consist of:
- 1 Turbine extended kit; TKIE
- 1 Turbine Relay board; TA-10
- 1 Beacon PSU; 24VDC or 230VAC
- 1 Flowire unit; FCDC2
- 1 24VDC Flowire PSU
Multiple TFIX'es with beacon in the EX zone, where all controlling equipment is located in the server room.
For every sixth TFIX with beacon you need:
- 1 Turbine compact Kit; TKIS-2
- 1 Multi-relay board; MRBD
- 1 24VDC PSU: for the MRBD
- 1 Flowire unit; FCDC2
- 1 24VDC Flowire PSU
- 6 Relay boxes; IRR-3
- 6 Beacons; BEX24O or BEX230O
- 6 Beacon Power supplies; 24VDC or 230VAC