− | If the Pulse Server is an [[:Stations#INCA_stations|Inca station]] you must select a different device (Turbine) as the IC-EDGE Controller. <br> | + | If the Pulse Server is an [[:Category:Stations#INCA_stations|Inca station]] you must select a different device (Turbine) as the IC-EDGE Controller. <br> |
Maximum number of devices with TCIV as the controller is 4. <br> | Maximum number of devices with TCIV as the controller is 4. <br> | ||
Revision as of 11:16, 10 September 2019
This article describes how to upgrade from Pulse (VS-IS 4.x) to IC-EDGE.
Prerequisite
- You can upgrade from Pulse (VS-IS 4.x) to IC-EDGE, but the whole system needs to run with the same Turbine software (VS-IS 5.0 or newer).
- In an IC-EDGE System, INCA intercoms cannot be used as the Edge Controller.
- TCIV video intercoms should not be used as the Edge Controller for systems exceeding 4 devices.
- VS-IMT can be used for station discovery and upgrade but must not be used to configure IC-EDGE.
Pulse to IC-EDGE Licenses
Pulse licenses will be honored in an IC-EGDE System. This means that when you upgrade firmware from VS-IS 4.x to 5.x your Pulse licenses will work for IC-EDGE.
More information regarding licensing in IC-EDGE can be found here.
Select IC-EDGE Controller
If the Pulse Server is an Inca station you must select a different device (Turbine) as the IC-EDGE Controller.
Maximum number of devices with TCIV as the controller is 4.