Difference between revisions of "Door Opening using Dummy Number (Event Handler)"
From Zenitel Wiki
(→Situation) |
(→Solution) |
||
Line 3: | Line 3: | ||
==Solution== | ==Solution== | ||
+ | When the operator gets a signal that there is someone at the door he should dial a 'dummy' number, then press digit 6 to operate a relay output (i.e. a [[RCO]]). | ||
In the example below any station can dial 9545 + 6 to trigger [[RCO]] 4 for 2 seconds, and disconnect with success-tone. | In the example below any station can dial 9545 + 6 to trigger [[RCO]] 4 for 2 seconds, and disconnect with success-tone. | ||
Use the two-step event trigger, [[Event trigg on dialing digits|feature 105]]. | Use the two-step event trigger, [[Event trigg on dialing digits|feature 105]]. | ||
− | |||
==Programming== | ==Programming== |
Revision as of 12:06, 20 November 2008
Situation
Some gates are not equipped with door stations, but the operator should use the same Door opening procedure to open the door.
Solution
When the operator gets a signal that there is someone at the door he should dial a 'dummy' number, then press digit 6 to operate a relay output (i.e. a RCO). In the example below any station can dial 9545 + 6 to trigger RCO 4 for 2 seconds, and disconnect with success-tone. Use the two-step event trigger, feature 105.
Programming
In AlphaPro, Directory & Features, press "Insert" to create a directory number, feature 105, for each door. Directory number 9545 is included by default.
In AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:
Event Owner: | The operator station or a UDP group |
Event type: | 25 – Event Trigger w/User Parameter |
Subevent: | 6 |
When change to: | ON |
When related to: | Directory number, Id: 9545 |
Action: | RCO 4 ON 20 |
$DISCON_ST L%1.dir U2 |
Explanation
Subevent 6: digit 6 When Change to ON: When the digit is pressed (not released) RCO 6 ON 20: Pulse RCO 6 for 2,0 seconds $DISCON_ST L%1.dir U2: Disconnect the station with successtone