− | A '''SuperUser''' is a user with access to all features in the system. A SuperUser is assigned to [[Class of service]] 16. By default there is one SUperUser in an exchange. This is the station connected to [[physical number]] 1 ([[directory number]] 101). This station is also by default set to receive error messages generated by the system | + | A '''SuperUser''' is a user with access to all features in the system. A SuperUser is assigned to [[Class of service]] 16. By default there is one SUperUser in an exchange. This is the station connected to [[physical number]] 1 ([[directory number]] 101). This station is also by default set to receive the following error messages generated by the system: |
+ | * Line error (faulty station line) | ||
+ | * Board error ([[AMC-IP]] cannot communicate with the board reported down) | ||
+ | * Device error ([[RIO]] or slave [[module]] communication failure) | ||
+ | * AGA error ([[AlphaNet]] or [[MultiModule]] audio line error) | ||
+ | |||
+ | The error reporting is configured from [[Exchange_%26_System_%28AlphaPro%29#Faults|Exchange & System -> RCI -> Faults]]. |
Revision as of 22:33, 1 September 2008
A SuperUser is a user with access to all features in the system. A SuperUser is assigned to Class of service 16. By default there is one SUperUser in an exchange. This is the station connected to physical number 1 (directory number 101). This station is also by default set to receive the following error messages generated by the system:
- Line error (faulty station line)
- Board error (AMC-IP cannot communicate with the board reported down)
- Device error (RIO or slave module communication failure)
- AGA error (AlphaNet or MultiModule audio line error)
The error reporting is configured from Exchange & System -> RCI -> Faults.