Actions

INCA Station Kit Restore Factory Defaults

From Zenitel Wiki

Revision as of 10:46, 25 October 2016 by Roarl (talk) (Restore with Static IP)

Restore to Factory Default for IP Stations without Display and Key:


For IP Master Station kits with display, see: INCA Display Station Restore Factory Defaults

The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.

Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.

Load Defaults without KEY.PNG



Restore with Static IP

  1. While pressing the button, power up the station kit.
  2. When the station kit LED starts blinking, release the button after exactly 2 blinks.
  3. Let the LED blink for exactly 2 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
  5. Release the button and the station kit will restart with the factory default settings.
Factory default values
Station Mode Pulse
Station IP address 169.254.1.100
AlphaCom IP address 169.254.1.5
Username* admin
Password* alphaadmin
* Software 01.06 and earlier: ADMIN/alphacom)



Restore with Activated DHCP

The DHCP option is available from software version 01.07.

  1. While pressing the button, power up the station kit.
  2. When the station kit LED starts blinking, release the button after exactly 2 blinks.
  3. Let the LED blink for exactly 4 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
  5. Release the button and the station kit will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: (determined by DHCP server)
  • AlphaCom IP address: 169.254.1.5
  • Username: admin (Software 01.06 and earlier: ADMIN)
  • Password: alphaadmin (Software 01.06 and earlier: alphacom)