Actions

Recall

From Zenitel Wiki

Revision as of 14:16, 2 September 2010 by Asle (talk) (Optional User Interface)

The Recall function let you record a message from a station, and then dispatch the recorded message as a Group Call. The function is used to prevent feedback problems when making Group Calls. The recorded message is temporary stored. It is deleted when the groupcall is finished. Maximum duration of a recall message is approx. xx minutes.

Directory numbers

Creating a new Recall number 9089 for group 6

Default directory numbers for "recall" broadcast:

  • 9084: Recall to group 1 (all)
  • 9085-9088: Recall to groups 2 - 5
  • 9101: Recall to global group 1 (for AlphaNet)

More recall numbers can be added from AlphaPro if required. In the Directory & Features window, select Insert and select Feature 113 and ID = local group number. Enter any free directory number and an appropriate display text.

The recall function can also be activated via a two-step operation, using the feature code 765. Dial 765 + group number.

User interface

Default User Interface

To initiate a group call using the recall function:

  1. Dial the recall number (e.g. 9084, or 765+84)
  2. Press M-key, record message
  3. Release M-key, listen to the recording
  4. Press 8 to dispatch the message, M to do a new recording, 7 to repeat the message or C to cancel

Using the recall function from a telephone:

  1. Dial the recall number (e.g. 9084, or 765+84)
  2. Press the *-button, record message
  3. Press the #-button to stop the recording and listen to the message
  4. Press 8 to dispatch the message, * to do a new recording, 7 to repeat the message or hang up to cancel

Optional User Interface

The user interface can be altered by modifying parameter 2 of the recall directory number. By default this parameter 2 is 0.

Options:

Value parameter 2 Function
1 After the playback to group ends, the groupcall and the initiator station proceed to normal Group Call mode, and can use M-key to talk into the group
2 If the initiator station disconnect during the playback to group, the message is terminated immediately
8 The initiator station will not listen to the playback to the group
32 The message is dispatched when pressing C or hanging up (no need to confirm by '8')
128 There will be no gong before the groupcall
256 The group is a global groupcall
512 There is no need to use M-key during the recording




  • If parameter 2 = 1 After the playback to group ends, the groupcall and the initiator station proceed to normal Group Call mode, and can use M-key to talk into the group
  • If parameter 2 = 2: If the initiator station disconnect during the playback to group, the message is terminated immediately
  • If parameter 2 = 8: The initiator station will not listen to the playback to the group
  • If parameter 2 = 32 the message is dispatched when pressing C or hanging up (no need to confirm by '8')
  • If parameter 2 = 128 there will be no gong before the groupcall
  • If parameter 2 = 256 the group is a global groupcall
  • If parameter 2 = 512 there is no need to use M-key during the recording

You can combine the varios options. If parameter 2 = 544 (i.e. 512+32) there will be no need for M to record, and the message is dispatched when pressing C:

  1. Dial the recall number (e.g. 9084)
  2. Record message (no M-key)
  3. Press C or hang up to dipatch the message

This option can be useful when using the recall function from telephones.

  • Digit '7' (or '#') can be used to stop the recording and listen to the message. Otherwise same as normal mode. M-Press (or '*') is required restart a recording.
  • Digit '0' will delete the recording and cancel the operation

Simultanous recodings

Hardware and software requiements

Hardware: The recall function can be used on all AMC-IP hardware versions (red or black PCB).

Software: Recall is available from AMC software version 11

License: Recall requires an Audio Messaging license.