Upgrade from Pulse to IC-EDGE
From Zenitel Wiki
This article describes how to upgrade from Pulse system (VS-IS 4.x) to an IC-EDGE System.
Contents
Definitions
Pulse System:
- In a Pulse system the Turbine devices are running firmware 3.x or 4.x.
- In a Pulse system the INCA devices are running firmware 2.9 or earlier.
IC-EDGE System:
- In a Pulse system the Turbine devices are running firmware 5.x.
- In a Pulse system the INCA devices are running firmware 2.10 or newer.
Prerequisites
- When upgrading a Pulse System to Edge, all devices needs to run the same Turbine software (VS-IS 5.0 or newer).
- In an IC-EDGE System, INCA stations cannot be used as the Edge Controller.
- TCIV video intercoms should not be used as the Edge Controller for systems exceeding 4 devices.
- VS-IMT can be used for station discovery and upgrade, but should not be used to configure Edge.
Pulse to Edge Licenses
Pulse licenses will be honored in an IC-EGDE System. This means that when you upgrade firmware from VS-IS 4.x to 5.x your Pulse licenses will work for Edge.
More information regarding licensing in Edge can be found here.
Select Edge Controller
The Edge Controller must be a Turbine device. If the current Pulse Server is an Inca station, you must select a different device (Turbine) as the Edge Controller.
Upgrade the Stations
In an IC-EDGE System all station must be upgraded to Edge. You cannot mix Edge and Pulse devices.
Make sure all Turbine station runs 5.0.3.0 or newer.
Inca stations must run 02.10.3.0 or newer.
Software can be found here.
Upgrade procedure using VS-IMT can be found here.
Manual upgrade procedure can be found here.
Edge Configuration
Detailed information on how to configure Edge can be found here.