Actions

Recall

From Zenitel Wiki

Revision as of 11:24, 2 September 2010 by Asle (talk) (Directory numbers)

The Recall function let you record a message from a station, and then dispatch the recorded message as a Group Call. The function is used to prevent feedback problems when making Group Calls. The recorded message is a temporary message, which is discarded when the Group Call is finished.

Directory numbers

Creating a new Recall number 9089 for group 6

Default directory numbers for "recall" broadcast:

  • 9084: Recall to group 1 (all)
  • 9085-9088: Recall to groups 2 - 5
  • 9101: Recall to global group 1 (for AlphaNet)

More recall numbers can be added from AlphaPro if required. In the Directory & Features window, select Insert and select Feature 113 and ID = group number. Enter any free directory number and an appropriate display text.

The recall function can also be activated via a two-step operation, using the feature code 765. Dial 765 + group number.

User interface

Default User Interface

To initiate a group call using the recall function:

  1. Dial the recall number (e.g. 9084, or 765+84)
  2. Press M-key, record message
  3. Release M-key, listen to the recording
  4. Press 8 to dispatch the message, M to do a new recording, 7 to hear again or C to cancel

Using the recall function from a telephone:

  1. Dial the recall number (e.g. 9084, or 765+84)
  2. Press the *-button, record message
  3. Press the #-button to stop the recording and listen to the message
  4. Press 8 to dispatch the message, * to do a new recording, 7 to hear again or hang up to cancel

Optional User Interface

The user interface can be altered by modifying parameter 2 of the recall directory number.

If parameter 2 = 544, there is no need to use M-key, and the message is dispatched when pressing C.

  1. Dial the recall number (e.g. 9084)
  2. Record message (no M-key)
  3. Press C or hang up to dipatch the message

This option can be useful when using the recall function from telephones.

  • '#' or '7' must then be used to stop recording and do pre-listen. Otherwise same as normal mode. M-Pres is required restart a recording.
  • 0 to delete recording, cancel

Hardware and software requiements

Hardware: The recall function can be used on all AMC-IP hardware versions (red or black PCB).

Software: Recall is available from AMC software version 11

License: Recall requires an Audio Messaging license.