Actions

ENA Amplifier - Report faults to Display Station

From Zenitel Wiki

Revision as of 11:06, 12 April 2018 by Asle (talk | contribs)
AlphaCom icon 300px.png
Amplifier faults, such as Speaker Line errors, can be reported to display stations

Faults in the ENA Amplifier can be reported to a display station, e.g. to IP Desktop, DualDisplay or CRMV station. This is achieved by using event 43 - Station Fault Report, which is triggered whenever the ENA amplifier reports a fault.

In order to have one common event for all ENA amplifiers, include the amplifiers in an UDP Group. Here UDP Group 3 is used as an example.

In AlphaPro, select Exchange & System > Events, and Insert a new event with the following properties:

Event 43 is used to report amplifer errors


Action Command:

IF %chg(1,0)
$STM %1.ref L164 U%op(70,+,%sev) '(%1.dir) %2.nam'
STOP
ENDIF
$CANM %1.ref L164 NM253 U%op(70,+,%sev)



The Event string will send a station-mail ($STM) to station 164 for all new fault codes. When a fault is reported "OFF" the mail message is automatically deleted. ($CANM)

The priority of the mail will be the fault type + 70. The mail text will contain the directory number of the amplifier and the default fault text.